21
Salt level too low (below 2500 ppm, Low Salt LED on).
Salt level too high (high Salt LED on).
Low pH. Low pH oxidizes chlorine quickly, making it difficult to maintain desired
chlorine levels.
Adjust pH levels to re-balance water.
Warm pool water increases chlorine demand—increase Desired Level% or
filter run time.
Cold water (below 50F) can cause HydroSalt
™
to stop generating (Generating
LED flashing).
Excessive scaling on cell.
High level of phosphates in pool water.
Some yellow algae treatments will use chlorine at a very high rate and deplete
the residual free chlorine. Manually shock the pool if indicated in the directions
on the algae treatment. It still may be a matter of days before the pool returns to
“normal” and chlorine tests will show the desired 1-3ppm free chlorine reading.
9. “PCB” displayed and all 4 LEDs are illuminated.
A possible printed circuit board fault has been detected. Call for service.
REPLACEMENT PART LIST
Item No.
Part description