12
restored.
CHECK CELL:
If flashing, either the cell efficiency is reduced or it is time for regularly
scheduled cell inspection. In either case, inspect the cell and clean if necessary.
Pressing the “diagnostic” button next to the display for 3 seconds will stop the
flashing LED.
When illuminated steady, cell efficiency is greatly reduced and HydroSalt
™
has
stopped producing chlorine. Inspect, clean or replace if necessary.
SALT DISPLAY
The Salt Display shows the current salt concentration of the pool water. Readings are in
ppm (parts per million). If Metric units (grams per liter) are preferred, push the “diagnostic”
button next to the display once. The display will now show the pool water temperature in
degrees Fahrenheit. With the temperature displayed, move the main switch from AUTO to
SUPER CHLORINATE to AUTO. The temperature display will instantly change to
degrees Celsius. Repeat this process to switch back to USA units (Fahrenheit).
OPERATION
By familiarizing yourself with the operation of the HydroSalt
™
generator, you can achieve
maximum performance for your pool. When chemical levels are in the recommended
range, there are FOUR factors that you can control which directly contribute to the
amount of chlorine the HydroSalt
™
will generate:
Filter time each day (hours)
The amount of salt in the pool
The “Desired Level %” setting
Stabilizer level in the water.
To find the optimum “Desired Level %” setting, start at a fairly high setting and work
downward. It will take a few days of adjustments to find the ideal setting for your pool.
Once determined, it should only take minor adjustments. The HydroSalt
™
control will not
produce chlorine at temperatures below 50’F If your pool water is colder than 50’F, you
Summary of Contents for HydroSalt
Page 18: ...17...