16
Plumbing
Ensure that the HydroSalt
™
installation does not constitute a cross connection with the
local potable water supply. Consult local plumbing codes.
The cell and flow switch are plumbed in the return line to the pool. Install after
(downstream) all the pool equipment (filter, heater, solar, etc.). The kit included in the
HydroSalt
™
provides the necessary plumbing components for:
2” (51mm) rigid PVC piping installation for in ground pools
1 1/2-1 1/4
〞
(38-32mm) flexible hose connections for above ground pools
For proper plumbing, refer to the overview diagram on page 19.
Flow switch
:
IMPORTANT:
To insure proper operation, verify that the arrow on the flow switch (located
on the side) points in the same direction of water flow. There must be 12” of a straight
pipe run before the flow switch.
Electrolytic Cell:
Install using the unions provided. Tighten by HAND for a watertight seal. For pool/spa
combination systems with spillover, use configurations #2 or #3 on page 18. Allow
chlorination for both the pool and spa during spillover but preventing over chlorination
when operating the spa only.
Summary of Contents for HydroSalt
Page 18: ...17...