![Ruwac industriesauger NA 7-11 Instruction Manual Download Page 18](http://html1.mh-extra.com/html/ruwac-industriesauger/na-7-11/na-7-11_instruction-manual_1503262018.webp)
9. Emptying / Cleaning
The viewing panel should be regularly
wiped clean, inside and out, using a
soft cloth
Lift the shut-off valve to allow insertion
of the hose. (arrowed)
The window of the fill level indicator
should also be regularly wiped clean,
inside and out, using a soft cloth.
To insert the container into the housing, reverse the order.
Switch off the vacuum unit.
Pull the container out of the
housing using the handle.
Lift the moisture separator housing.
Clean the moisture separator using a
strong water jet. Dry until only slightly
moist (use compressed air if neces-
sary).
If despite being cleaned the moisture
separator is still dirty it must be
replaced. Remove the moisture sepa-
rator from the housing. Then insert a
new moisture separator.
The shut-off valve in the liquid contain-
er avoids the possibility that after the
container has been cleaned an attempt
may be made to run the suction unit
without reinstalling the swirl filter.
9.2 Cleaning / Changing the moisture separator
9.3 Cleaning / Checking the viewing panel
9.4 Assembly of the wet separator
18