![Ruwac industriesauger NA 7-11 Instruction Manual Download Page 13](http://html1.mh-extra.com/html/ruwac-industriesauger/na-7-11/na-7-11_instruction-manual_1503262013.webp)
13
7. Accident preventionr
1. Guards, mechanical hazard
protection
2. Electrical hazard protection
3. Protection against
hazardous media
All moving parts have fixed guards
which are securely fastened and can
only be removed using tools.
Residual risk:
Using tools to remove the fastenings
for the fixed guards when the unit is
still running can cause injury.
All live components on the unit are
insulated or covered with fixed,
securely fastened guards which can
only be removed using tools. The
machine complies with the require-
ments of Protection Class I as per
EN 60 335-1.
Residual risk:
Electric shock hazard. Using tools to
remove fixed guards when the power
supply is not unplugged can cause
injuries due to electric shock.
Risk of explosion associated with gas
formation: Installation of a degasifica-
tion valve.
On finishing work, always store the
wet separator in a well-ventilated area.
Residual risk:
Failure to check the degasification
valve is working correctly.
Storing the wet separator without
cleaning it.
The wet separator has the following hazard prevention features: