background image

 

 

Multibeam 2 

 

 

 

 

User Manual 

 

 

 

 

 

Professional Entertainment Technology 

Summary of Contents for Multibeam 2

Page 1: ...Multibeam 2 User Manual Professional Entertainment Technology...

Page 2: ...ility to use or reliance on the information contained in this manual The Martin logo the RUSH by Martin logo the RUSH by Martin name the Martin name and all other trademarks in this document pertainin...

Page 3: ...trol data link 14 Tips for reliable data transmission 14 Connecting the DMX data link 14 Fixture setup 15 Using the control menus 15 DMX function settings 15 Show settings 16 Fixture settings 18 Fixtu...

Page 4: ...concentrate the beam This product is for professional use only It is not for household use It product presents risks of severe injury or death due to fire hazards electric shock and falls Respect all...

Page 5: ...r until repairs have been completed Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected dev...

Page 6: ...vices to the MAINS OUT socket that accept this voltage and frequency Protection from burns and fire Do not operate the fixture if the ambient temperature Ta exceeds 40 C 104 F The surface of the produ...

Page 7: ...fety attachment for the weight that it secures must comply with EN 60598 2 17 Section 17 6 6 and must be capable of bearing a static suspended load that is ten times the weight of the fixture and all...

Page 8: ...g the product for the first time 1 Read Safety information on page 4 before installing powering operating or servicing the fixture 2 Unpack and ensure that there is no transportation damage before usi...

Page 9: ...re if the primary fastening method fails Mounting the fixture on a truss The fixture can be clamped to a truss or similar rigging structure in any orientation When installing the fixture hanging verti...

Page 10: ...ts Securing with a safety cable Secure the fixture with a safety cable or other secondary attachment that is approved for the weight of the fixture so that the safety cable will hold the fixture if a...

Page 11: ...he fixture can easily be disconnected from power Do not insert or remove live Neutrik PowerCon connectors to apply or cut power as this may cause arcing at the terminals that will damage the connector...

Page 12: ...in a linked daisy chain MAINS OUT throughput socket to MAINS IN input socket Using 12 AWG or 2 5mm2 cables from Martin you can link Maximum seven 7 RUSH Multibeam 2 fixtures in total at 100 120 V or M...

Page 13: ...is provided to connect the fixture to AC mains power 6 Mains power throughput See Safety information on page 4 The light grey Neutrik PowerCon socket can be used to supply power to other fixtures only...

Page 14: ...r long runs 24 AWG cable is suitable for runs up to 300 meters 1000 ft Heavier gauge cable and or an amplifier is recommended for longer runs The pin out on all connectors is pin 1 shield pin 2 cold a...

Page 15: ...menus press and hold the MENU button DMX function settings DMX function settings include the DMX address and Master Slave mode DMX addressing The fixture can be controlled using signals sent by a DMX...

Page 16: ...MASTER mode To adjust a fixture s MASTER SLAVE settings 1 Select SLAVE MODE and press the ENTER button 2 Use the UP and DOWN buttons to select from Master fixture runs a stand alone show sound activa...

Page 17: ...its show to be triggered by a music beat for example To turn on Music trig 1 Set BLACKOUT to No see above 2 Select SOUND STATE and press the ENTER button to confirm 3 Use the DOWN and UP buttons to s...

Page 18: ...ct Yes movable LED bar 2 inversion or No normal 3 Press the ENTER button to confirm or to return to the higher level of the menu structure without any change press the MENU button LED reverse To adjus...

Page 19: ...what software version is installed in the fixture 1 Select SOFTWARE VERSION and press the ENTER button to confirm The firmware version will be shown 2 To return to the higher level of the menu structu...

Page 20: ...icle buildup degrades performance causes overheating and will damage the fixture Damage caused by inadequate cleaning or maintenance is not covered by the product warranty The cleaning of external opt...

Page 21: ...fixture is dry before reapplying power Fuse replacement If the fixture is completely dead the fixture s primary fuse F1 may have blown and it may be necessary to install a new fuse This fuse is locate...

Page 22: ...22 RUSH Multibeam 2 User Manual partnership that will ensure the highest level of performance throughout the product s lifetime Please contact your RUSH by Martin supplier for details...

Page 23: ...255 Tilt 2 movement 50 170 4 0 255 Dimmer 0 100 5 Strobe 0 7 Open 8 131 Strobe slow fast 132 139 Open 140 181 Pulse effect fast close slow open 182 189 Open 190 231 Pulse effect slow close fast open 2...

Page 24: ...0 100 27 0 255 Green LED 6 0 100 28 0 255 Blue LED 6 0 100 29 0 255 White LED 6 0 100 30 0 255 Red LED 7 0 100 31 0 255 Green LED 7 0 100 32 0 255 Blue LED 7 0 100 33 0 255 White LED 7 0 100 34 0 255...

Page 25: ...2 Pre programmed shows 1 12 Sound State Off Music trig off On Music trig on Blackout No Fixture runs in stand alone mode when it is not receiving a DMX signal Yes Fixture blacks out when it does not r...

Page 26: ...place fixture s primary fuse Fixture does not react to music beat Sound activation disabled Sound level too low to activate music trigger Ensure that fixture is not connected to a DMX signal Check mas...

Page 27: ...a high voltage installation Ensure that fixture s DMX address matches address set on DMX control device Check that fixture DMX LED is on and if not check all DMX cables and connections Ensure that DMX...

Page 28: ...ng 0 100 Control and Programming Control options DMX stand alone master slave DMX channels 45 Stand alone trigger options Music trig Auto trig Setting and addressing Control panel with LCD display DMX...

Page 29: ...variation Thermal Cooling Forced air Maximum ambient temperature Ta max 40 C 104 F Minimum ambient temperature Ta min 0 C 32 F Included Items Power cable 6 A 18 AWG 0 75 mm2 UL listed H05VV F 1 5 m w...

Page 30: ...02003 Quick trigger clamp suspension vertically downwards only P N 91602007 Safety wire safe working load 50 kg P N 91604003 Related Items RUSH Software Uploader 1 P N 91611399 Ordering Information RU...

Page 31: ......

Page 32: ...Innovation Quality Performance...

Reviews: