background image

www.victorruoshui.co.kr 

18

   

이  자료는  저작권법에  따라  보호받는  저작물이므로  무단배포  및  무단복제를  금하며,  내용의  전부 
또는  일부를  이용하려면,  반드시  한국  VictorRuoshui  社  의  서면동의를  받아야  합니다.

 

“uAmA  ”or  “10A”input  terminal,  displayed  as  the 

right picture. 

2.  Turn  the  function/range  selection  knob  to  current 

range,  press  “SELECT”,  switch  to  AC  measurement 

mode,  then  connect  the  test  lead  to  the  tested  circuit 

in  series,  the  polarity  of  the  red  test  lead  and  the 

tested  current  value  will  be  displayed  on  LCD 

simultaneously. 

3. If “OL”  is displayed  on  LCD, it  indicates the  tested 

current  value  has  exceeded  the  present  range  limit, 

please  select  the  higher  range  to  complete  the 

measurement. 

     

  Note: 

a)

 

Do  not  measure  the  current

 

higher  than  10A  at 

Range  10A  and  higher  than  600mA              at  mA 

Range 

Summary of Contents for VR-86D

Page 1: ...instrument can measure DC and AC voltage DC and AC current Resistance Capacitance Frequency Duty Circle Transistor Diode and Continuity test And it also has the features of Bar Graph Unit Indication...

Page 2: ...en the gift box and take out the instrument carefully check the following accessories If any accessory was lost or damaged please contact the manufactory at once Digital Multimeter 1pc Operation Manua...

Page 3: ...tion to avoid the electric shock when measuring the voltage higher than 30V the current higher than 10mA AC Power Lines with Inductive Load and the AC Power Lines during the period of Electric Power F...

Page 4: ...it by the same type and electric specification battery Before replacement should keep the test lead off the tested point to make sure there is no any signal at the input terminal 6 When measuring elec...

Page 5: ...ecting the test lead with the current terminal to avoid damaging the instrument and endangering the safety of the users 10 Do not try to calibrate or repair the instrument should operate it by the spe...

Page 6: ...nal 14 Do not try to modify the inner circuit at will to avoid damaging the instrument and endangering the safety of the users 4 Safety Symbol Description Warning DCA High Voltage Dangerous ACA GND DC...

Page 7: ...get into the normal measuring status Press the button for more than 3 sec to turn on off the backlight 3 2 HZ DUTY Frequency Duty Circle selection button press the button to switch between the Frequen...

Page 8: ...aximum or minimum value will be held on LCD Under this circumstance there are no Bar Graph and Auto Power Off function hold pressing MAX MIN button for 2 seconds exit the MAX MIN mode 3 5 RANGE Auto R...

Page 9: ...RS232 symbol appears on LCD it indicates the instrument is getting into the status of data transmission Keeping pressing the button more than 2 seconds RS232 symbol disappears the data transmission i...

Page 10: ...nside will sound 5 times one minute before powering off there is a long sound one minute later and the instrument gets into the sleeping mode Press any key to restart the power 2 Press REL RS232 butto...

Page 11: ...ith CD then connect the instrument to PC by USB Cable and then can transmit the measuring data to PC it is convenient to record analyze process and print the measuring results etc Please refer the det...

Page 12: ...pcs 1 5V batteries AAA 7 battery 1 10 Dimension 192mm x 95mm x 48mm 1 11 Weight Approx 390g including batteries Technic Property 1 Accuracy a reading digits at 23 5 relative humidity 75 2 One year cal...

Page 13: ...arallel the polarity of the red test lead and the tested voltage value will be displayed on LCD simultaneously Note a Do not measure the voltage higher than DC 1000V or AC 750V b When measuring the hi...

Page 14: ...Overload protection 1000V DC or 750V AC peak value 9 AC Voltage ACV 1 Turn the function range selection knob to ACV DCV press SELECT button toswitch to ACV measurement mode Insert the red and black te...

Page 15: ...s 220V 380V 50Hz 400Hz 3 Connect the test lead to the tested circuit in parallel the polarity of the red test lead and the tested voltage value will be displayed on LCD simultaneously Note a Do not me...

Page 16: ...uty Circle indication 0 1 99 9 10 DC Current DCA 1 Insert the black test lead to COM input terminal and the red test lead to uAmA or 10A displayed as the right picture The maximum input respectively f...

Page 17: ...it indicates the test current value has exceeded the present range limit please select the higher range to complete the measurement Note a Do not measure the current higher than 10A at Range 10A and h...

Page 18: ...on between the test lead and tested circuit at once after measurement Range Accuracy Resolution 600uA 1 0 10d 0 1 A 6000uA 1 A 60mA 10 A 600mA 100 A 6A 1 2 10d 1mA 10A 10mA Max input current 10A less...

Page 19: ...ct the test lead to the tested circuit in series the polarity of the red test lead and the tested current value will be displayed on LCD simultaneously 3 If OL is displayed on LCD it indicates the tes...

Page 20: ...erwise it is possible to damage the instrument or endanger the safety of the users Cut the connection between the test lead and tested circuit at once after measurement Range Accuracy Resolution 600uA...

Page 21: ...nd black test lead separately to V Hz and COM input terminal 2 Connect the test lead to the tested resistance in parallel the tested resistance value will be displayed on LCD 3 Auto Range mode is pres...

Page 22: ...the reading incorrect to input any voltage when measuring the resistance If the voltage exceeds 250V over range protection voltage it is possible to damage the instrument and endanger the safety of t...

Page 23: ...on 3 Connect the RED test lead to the positive pole of the tested diode BLACK test lead to the negative pole 4 Read the present test result from LCD Note no Bar Graph display at Diode Range Note a If...

Page 24: ...Counter Voltage 3 0V Buzzer sound at less than 50 Open Voltage 0 5V Overload protection 250V DC AC peak value Warning Do not input the voltage at the range for safety 14 Capacitance C 1 Turn the funct...

Page 25: ...omplete the measurement 4 Read the present test result from LCD Note a When measuring the in circuit capacitor make sure all the power of the tested circuit has been turned off and all capacitors are...

Page 26: ...to V Hz and COM input terminal 2 Connect the test lead to the tested signal source in parallel Read the present test result from LCD Note no Bar Graph display at this range 3 When measuring Frequency...

Page 27: ...rwise it is possible to damage the instrument and endanger the safety of the users b Cut the connection between the test lead and c tested circuit at once after measurement Range Accuracy Resolution 1...

Page 28: ...terminal of EBC of NPN or PNP 4 Read the present test result from LCD Note a Do not input the current or voltage at the input terminal of uAmA COM or transistor accessory otherwise it is possible to d...

Page 29: ...ut terminal the positive end into the uAmA input terminal 3 Connect the sensor of the temperature cable to the surface or inside of the tested object displayed as the right picture 4 Read the present...

Page 30: ...Otherwise the accuracy can t be assured c Do not input the voltage at Temperature Range caution to avoid damaging the instrument Range Accuracy Resolution 20 400 1 0 50d 0 1 400 1000 1 5 15d 1 0 750 1...

Page 31: ...n to get into the Relative Value Measurement mode Keep holding REL RS232 button more than 2 seconds RS232 symbol is displayed on LCD it indicates it is the status of the instrument connecting with PC...

Page 32: ...D displays symbol should replace the batteries as the following steps 5 1 Loose the screw that fixes the batteries and remove the battery case 5 2 Remove the spent 1 5V batteries and replace them by t...

Page 33: ...n manual is subject to chance without notice The contents in the instruction manual are considered to be correct if the users find any errors or pretermissions etc please contact the manufacturer The...

Reviews: