www.victorruoshui.co.kr
이 자료는 저작권법에 따라 보호받는 저작물이므로 무단배포 및 무단복제를 금하며, 내용의 전부 또는 일부를 이용하려면, 반드시 한국 VictorRuoshui 社 의 서면동의를 받아야 합니다.
(
5
)
Measurement for earth resistance
Press TEST key after connecting the Test Leads.
The Main Screen displays
“- - - -” message.
The measured earth resistances RE value and related information are displayed on the Main Screen when the
measurement is finished.
Press
key to read RH
,
RS, UST
and
RK values.
Note: the residual value is valid in earth resistivity measurement.
Figure 11
Note
The results in simplified measurement include auxiliary earth resistance. Thus, the displayed value may cause
error if the auxiliary earth resistance is over high.
The measurement result may be incorrect if interference voltage is higher than 5v, and the noise mark