background image

Installation Manual 

Chapter 6    Cable Connection 

 

6-3

 

 

6.1.1.3 

 

Connecting the RCMS Asyn Interface to 
the CONSOLE Interface 

The RCMS converter cable converts the 68-pin RCMS asyn interface into eight RJ45 
connectors, and then connects to the RJ45 connector of the console port of switch/router. 

This mode applies to such modules as RCMS-16 and RCMS-8. 

Table 6-4 Connect the RCMS asyn interface to the CONSOLE interface 

Equipment 

Cable 1 

Peer 

RCMS-16 

RCMS-8 

RCMS converter cable 

CONSOLE interface 

6.1.2  

 

Connecting A Synchronous Interface 

6.1.2.1 

 

V.24 mode   

The syn interface of the router line card working under V.24 DTE mode is connected to the 
peer working under the V.24 DCE mode through V.24 DTE cables. While the syn interface 
working under V.24 DCE mode is connected to the peer working under the V.24 DTE mode 
through V.24 DCE cables. 

This applies to the V.24 DTE/ V.24 DCE mode of such line cards as SIC-1HS and 
NMX-4HSH.  

Table 6-5 Connect the syn interface of the router working under the V.24 mode. 

Equipment 

Mode 

Cable 1 

Peer 

V.24 DTE mode 

V.24 DTE cables 

V.24 Modem 

The syn 
interface line 
card with 
DB26 interface 
such as 
SIC-1HS, 
NMX-4HSH 

V.24 DCE mode 

V.24 DCE cables 

Equipments working 
under V.24 DTE mode 

6.1.2.2 

 

V.35 mode 

  The syn interface of the router line card working under V.35DTE mode is connected to 

the peer as GV converter and V.35 Modem through V.35 DTE cables. While the syn 
interface working under V.35 DCE mode is connected to the peer working under the 
V.35 DTE mode through V.35DCE cables. 

This applies to the V.35 DTE/V.35 DCE mode of such line cards as SIC-1HS, and 
NMX-4HSH.  

Summary of Contents for RSR10 Series

Page 1: ...Ruijie RSR10 RSR20 Series Routers Hardware Installation Manual V2 00...

Page 2: ...manual shall solely remain with Ruijie Networks Ltd Without our written permission this document may not be excerpted reproduced transmitted or otherwise in all or in part by any party in any means R...

Page 3: ...d have experience in installing and configuration routers This manual consists of the following chapters Chapter 1 Product Overview Presents an introduction to Ruijie RSR10 RSR20 series routers and th...

Page 4: ...RSR10 RSR20 series routers please refer to the related command reference manual and configuration guide Obtaining Documentation You can obtain the documentation you need through the following channels...

Page 5: ...problems Technical Support Website http support ruijie com cn Technical Support E mail service ruijie com cn Call center hot line 4008 111 000 Service complaint hot line 0591 83057315 Target Readers T...

Page 6: ...Warning Warning danger or alert in the operation Caution Precaution attention or reminder in the operation Note Note prompt tip or any other necessary supplement or explanation for the operation...

Page 7: ...9 1 3 8 SIC 2FXS Interface Card 1 41 1 3 9 SIC 2FXO Interface Card 1 42 1 3 10 SIC 1CE1 Interface Card 1 43 1 3 11 SIC 3G TD Interface Card 1 44 1 3 12 SIC 3G CDMA Interface Card 1 48 1 3 13 SIC 3G WC...

Page 8: ...Cabinet 3 2 3 2 2 Mounting on the Workbench 3 5 3 3 Installing the Power Cable and Grounding Cable 3 5 3 4 Connecting the Console 3 6 3 5 Installing Cards 3 6 3 5 1 Installing Line Cards 3 6 3 5 2 Re...

Page 9: ...3 6 1 3 Connecting An E1 Interface 6 4 6 1 4 Connecting the Console Interface 6 5 6 2 Order Information 6 5...

Page 10: ......

Page 11: ...02 1 1 1 RSR10 02 1 1 1 1 Overview The RSR10 02 modular router is an enterprise oriented network product independently developed by Ruijie Networks Designed with a modular structure and 32 bit high pe...

Page 12: ...S T interfaces two sync serial interfaces two 3G interface cards four Layer 2 switching Ethernet interfaces and 16 asyn serial interfaces to provide the high density remote OA solution The E1 interfac...

Page 13: ...he test of telecom access network equipment by the MII 1 1 1 3 Indicators and Appearance Figure 1 1 Front panel of Ruijie RSR10 02 router 1 Indicator 2 Console 3 Interface Ethernet 0 0 4 Interface Eth...

Page 14: ...EXE mode The router version information includes the slot number of each module 1 1 1 4 Parameters The following table lists the parameters of RSR10 02 Item RSR10 02 Default Configuration One Console...

Page 15: ...is compatible with the standard configuration GUIs of the mainstream products and delivers easy configuration The RSR20 04 router provides a great variety of network security features It delivers a se...

Page 16: ...and the ISDN S T interface complies with ITU T I 430 The sync serial port can connect the networks such as DDN frame relay and X 25 These make the router suitable as an access router for large medium...

Page 17: ...rnet 0 0 5 Interface Ethernet 0 1 Panel indicator description Indicator Description Status Solid on the system works well OFF or flash means the system does not work well S 1 4 Green on when a SIC car...

Page 18: ...t one AUX port and two 10 100M Ethernet ports SIC card slot 4 In according with user s requirement configure up to four SIC cards Processor RISC high performance network processor BOOT ROM 2MB SDRAM 1...

Page 19: ...and in the future Enables ease of management Makes no damage to interfaces in a complicated financial site environment Connects asyn interface terminals entwork terminals and PCs at the same time Add...

Page 20: ...remote OA solution Moreover RSR20 14 comes with one NMX slot that supports 24 Layer 2 switching Ethernet interfaces The E1 interface complies with ITU T G 703 the ISDN U interface complies with ITU T...

Page 21: ...lot indicator Panel indicator description Indicator Description SYSTEM Flashing Green the system is starting Green the system runs stably Red the system works abnormally POWER On the system is powered...

Page 22: ...ace 1 2 2 4 Parameters The following table lists the feature parameters of Ruijie RSR20 14 Item RSR20 14 Default Configuration One Console port one AUX port two USB interfaces and three 10 100M Ethern...

Page 23: ...structure and 32 bit high performance RISC microprocessor technology it is based on our independently developed high performance network operating system platform which is compatible with the standard...

Page 24: ...ed with the supported card type The SIC line cards are divided into 4 types as shown in the following table SIC Type Supported SIC line card Class A SIC 1A SIC 8A SIC 1B U SIC 1B S T SIC 2FXS SIC 2FXO...

Page 25: ...with ITU T G 961 ANSI T1 601 and the ISDN S T interface complies with ITU T I 430 The sync serial port can connect the networks such as DDN frame relay and X 25 These make the router suitable as an a...

Page 26: ...ndicator description Indicator Description SYSTEM Flashing Green the system is starting Green the system runs stably Red the system runs abnormally POWER On the system is powered on Off the system is...

Page 27: ...t2 8 SIC card slot1 9 Slot number indicator 9 Power switch 10 Enclosure ground interface 11 Input power interface Note If you cannot determine the number of the slot where the current module resides y...

Page 28: ...erprise oriented network product independently developed by Ruijie Networks Designed with a modular structure and 32 bit high performance RISC microprocessor technology it is based on our independentl...

Page 29: ...T SIC 2FXS SIC 2FXO Class B SIC 1HS SIC 3G TD SIC 3G CDMA SIC 3G WCDMA SIC 1HS V35 Class C SIC 1CE1 SIC 1E1 F Class D SIC 4ESW The following table shows the SIC cards suported by the RSR20 24 slots C...

Page 30: ...nterface complies with ITU T G 703 the ISDN U interface complies with ITU T G 961 ANSI T1 601 and the ISDN S T interface complies with ITU T I 430 The sync serial port can connect the networks such as...

Page 31: ...iption SYSTEM Flashing Green the system is starting Green the system runs stably Red the system works abnormally POWER On the system is powered on Off the system is not supplied with power S 1 4 Green...

Page 32: ...C D For the line card classification see the overview section 1 NMX card slot6 2 NMX card slot5 3 SIC card slot1 4 SIC card slot2 5 SIC card slot3 6 SIC card slot4 7 Power switch 8 Enclosure ground i...

Page 33: ...0Hz Whole system power consumption 50W Operating ambient temperature 0 45 C Storage ambient temperature 40 70 C Operating humidity 10 90 RH 1 3 SIC Card Introduction This section describes the feature...

Page 34: ...ing V 24 V 35 with automatic cable identification Rate The sync port of a single sync card supports 9600 8 192M bps LED Two One port LINK status LED which turns on when the connection to the physical...

Page 35: ...V 24DTE cable V 24 DCE One end of this cable is the DB25 female connector the other end is the DB26 male connector V 24DCE cable V 35 DTE One end of this cable is the DB34 male connector the other end...

Page 36: ...interface Pay attention to connectors when purchasing cables For the use of cables see the chapter 6 1 3 2 SIC 1HS V35 Sync Interface Card Product model SIC 1HS V35 1 3 2 1 Appearance and Indicators F...

Page 37: ...supports 9600 8 192M bps LED Two One port LINK status LED which turns on when the connection to the physical link is set up and the upper layer protocol is up One link card RDY status LED indicator w...

Page 38: ...SDN U interface card SIC 1B U The SIC 1B U is the Class A line card which can be used by the slot marked with A Figure 1 14 Appearance of the 1 port ISDN S T U interface card SIC 1B S T The SIC 1B S T...

Page 39: ...e Standard compliance ITU T I 430 Q 921 Q931 Operating Temperature Operating temperature 0 C 45 C Storage temperature 40 C 70 C Humidity Operating humidity 10 90 EMI GB 9254 1998 Class A EMC EMS GB T...

Page 40: ...15 Appearance of 1 port non channelized E1 card SIC 1E1 F The SIC 1E1 F is the Class C line card which can be used by the slot marked with C Panel indicator description Indicator Description Link Sol...

Page 41: ...balanced cable Balanced cable with crystal connector One end is the DB9 male connector and the other end is the RJ45 crystal connector The characteristic impedance of the cable is 120 Balanced cable w...

Page 42: ...g Non balanced cable One end is the DB9 male connector and the other end is attached with two male BNC connectors The characteristic impedance of the cable Non balanced cable No router cables are ship...

Page 43: ...itting on the port OFF means no data is transmitting on the port 1 3 5 2 Attributes of the SIC 4ESW Card The basic attributes are as below SIC 4ESW Number of ports Four Interface type Four RJ45 connec...

Page 44: ...inal devices such as PC routers etc If the device supports the MDI MDIX self adaptation the straight or crossover cable can be used Considering the possibility of making this cable by users themselves...

Page 45: ...6 RX orange 6 RX orange 1 3 6 SIC 8A Interface Card SIC card model SIC 8A 1 3 6 1 Appearance of the Module and Indicators Figure 1 17 Appearance of 8 port asyn interface card The SIC 8A is the Class...

Page 46: ...o 115200 bps band rate including 9600 19200 38400 57600 and 115200 bps Flow control Each asyn serial interface supports hardware and software auto flow control Operating Temperature Operating temperat...

Page 47: ...description of the cable pin definition is as bolow Signal description RT45 1 2 3 4 5 6 7 8 HPDB68M CTS 1 39 43 47 51 55 59 63 67 DSR 2 5 9 13 17 21 25 29 33 RXD 3 38 42 46 50 54 58 62 66 GND 4 4 8 1...

Page 48: ...inition of the cable pin please refer to the table in the asyn cable with 1 to 8 crystal connector section RJ45 crystal jack DB25 female connector convert connector RJ45 crystal jack DB25 female conne...

Page 49: ...interface card The SIC 1A is the Class A line card which can be used by the slot marked with A The interface card includes one RJ45 connector and one AUX interface It includes one RDY indicator and o...

Page 50: ...ature 0 C 45 C Storage temperature 40 C 70 C Humidity Operating humidity 10 90 EMI GB 9254 1998 Class A EMC EMS GB T 17618 1998 1 3 7 3 Module Cable The SIC 1A module uses rollover cables Note The AUX...

Page 51: ...the port is activated Off means the port is inactivated On means the card initialization after power on is done RDY Off means the card initialization after power on is unsuccessful 1 3 8 2 Attributes...

Page 52: ...Panel indicator description Indicator Description IN USE Solid on means the port is activated OFF means the port is inactivated ON means the card initialization after power on is done RDY OFF means t...

Page 53: ...by the slot marked with C Panel indicator description Indicator Description Link Solid on means the link is through OFF not connected ON means the card initialization after power on is done RDY OFF m...

Page 54: ...lanced cable one end is the DB9 male connector and the other end is attached with two male BNC connectors The characteristic impedance of the cable is 75 No router cables are shipped with the routers...

Page 55: ...EDGE Solid on means the EDGE service is effective Off means there is no EDGE service 1 3 11 2 Attributes of the SIC 3G TD The basic attributes are as below SIC 3G TD Number of ports SMA RF 1 RJ 45 1 I...

Page 56: ...s pole shaped antenna and 3m extension magnetic antenna Pole shaped antenna Pole shaped antenna specifications Attribute Parameter Frequency range 824 960 MHz 1710 2170 MHz VSWR 3 Input impedance 50 o...

Page 57: ...of 3m extension magnetic antenna ANT RJ3G3MA Attribute Parameter Frequency range 824 960 MHz 1710 2170 MHz VSWR 2 5 Input impedance 50 ohms Gain 3dBi Polarization Vertical Interface type SMA J Length...

Page 58: ...he slot Step 3 Close the slot in the opposite direction of OPEN Figure SIM slot Note 1 The gap of the SIM card should be aligned with that of the SIM slot In this manner the SIM card can be installed...

Page 59: ...means the firmware initialization of the line card is not complete or fails WWAN Solid on means the link is through Flashing means the data is being transmitted RSSI Solid on means the strong signal...

Page 60: ...perature 0 C 45 C Storage temperature 40 C 70 C Humidity Operating humidity 10 90 EMI GB 9254 1998 Class A EMC EMS GB T 17618 1998 Note When the module runs normally the RJ 45 interface does not need...

Page 61: ...s Gain 1 8 dBi 824 MHz 960 MHz 2 0 dBi 1710 MHz 2170 GHz Polarization Linear Interface type SMA Straight Plug Reverse Length 145mm Color Black Operating temperature 10 to 60 Cable length None 3m exten...

Page 62: ...ohms Gain 3dBi Polarization Vertical Interface type SMA J Length 224mm Color Black Operating temperature 40 to 60 Cable length 3m 1 3 12 4 Installing the SIM Card Step 1 Open the SIM slot according to...

Page 63: ...ppearance of SIC 3G WCDMA interface card The SIC 3G WCDMA is the Class B line card which can be used by the slot marked with B Panel indicator description Indicator Description RDY Solid on means that...

Page 64: ...l commissioning Cable SMA RF N A RJ45 Serial port cable Supported Rate HSDPA in theory 7 2 Mbps downlink and 5 76 Mbps uplink Operating Temperature Operating temperature 0 C 45 C Storage temperature 4...

Page 65: ...Frequency range 824 960 MHz 1710 2170 MHz VSWR 3 Input impedance 50 ohms Gain 1 8 dBi 824 MHz 960 MHz 2 0 dBi 1710 MHz 2170 GHz Polarization Linear Interface type SMA Straight Plug Reverse Length 145...

Page 66: ...magnetic antenna ANT RJ3G3MA Attribute Parameter Frequency range 824 960 MHz 1710 2170 MHz VSWR 2 5 Input impedance 50 ohms Gain 3dBi Polarization Vertical Interface type SMA J Length 224mm Color Bla...

Page 67: ...n be installed correctly 2 The SIM slot should be closed when there is no SIM card in it Otherwise there are risks of damaging the SIM slot 1 3 14 Other SIC Cards Ruijie Networks currently provides th...

Page 68: ...e NMX 24ESW Card The NMX 24ESW module offers 24 10 100M interfaces The basic attributes are as below NMX 24ESW Protocol 802 3 2000 Number of ports 24 Interface type 10Base T 100Base TX interface Envir...

Page 69: ...the NMX 4ESW L2 Card The NMX 24ESW L2 module offers 24 10 100M interfaces The basic attributes are as below NMX 24ESW 12 Protocol 802 3 2000 Number of ports 24 Interface type 10Base T 100Base TX inter...

Page 70: ...t 100Mbps or 10Mbps 1 4 3 2 Attributes of the NMX 2GEH Card The NMX 2GEH module offers 2 10 100 1000 Mbps Ethernet interfaces each supports optical and electrical connectors The electrical interface u...

Page 71: ...Maximum transmission distnace of 62 5 125um 550m Maximum transmission distnace of 50 125um 550m Maximum transmission distnace of 9 125um 10Km 1000BASE LH wavelength 1310nm Maximum transmission distnac...

Page 72: ...5DTE V 35DCE Standard compliance V 24 V 35 and cable auto identification Operating Temperature Operating temperature 0 C 45 C Storage temperature 40 C 70 C Humidity Operating humidity 10 90 EMI GB 925...

Page 73: ...e LINK indicator Panel indicator description Indicator Description Link Solid on means the link is through OFF not connected RDY ON means the card initialization after power on is done OFF means the c...

Page 74: ...lanced cable 4E1 non balanced cable The appearances of the above two cables are shown as blow 4E1 balanced cable One end is the DB25 male connector and the other end is attached with four RJ45 crystal...

Page 75: ...oviding RJ45 interfaces for twisted pairs supporting Ethernet ARP and 802 1Q protocols Supporting various WAN protocols including X 25 frame relay HDLC PPP and SLIP The network layer supports the TCP...

Page 76: ...ion of various network faults It provides a great array of statistics and information display functions to allow the users to easily know the network performance and running status It supports SNMP fo...

Page 77: ...multiple times of login It supports the real terminal The terminal logs in to the server via the router and act as a real terminal tty for the server not needing the modification of the old programs...

Page 78: ......

Page 79: ...ot wear any loose clothes as they may hook the components to avoid damages Therefore fasten your belts scarves and tuck well the sleeves Keep the tools and components away from human passages UPS is r...

Page 80: ...ement may be different for different products For the specifics refer to the information of the characteristic parameters of each product 2 2 2 Cleanness Requirements Dust also poses a major threat to...

Page 81: ...arts on the board directly with hand 2 2 4 Anti interference Requirements Anti interference means the electromagnetic and current interference Below please find the anti interference requirements Effe...

Page 82: ...ipation holes to ensure sufficient heat dissipation spaces You are recommended to mount the routers in the standard 19 cabinet Where no such cabinet is available the routers may also be mounted on lev...

Page 83: ...Chapter 2 Preparing for Installation 2 5 Related devices include HUB or switch CSU DSU or other DCE device The configuration terminal can be a terminal or a PC installed with the HyperTerminal Router...

Page 84: ......

Page 85: ...ocedure to install the Ruijie series routers to ensure a smooth installation and avoid any damage to the unit Preparations Read the second chapter and meet the requirements specified Install the route...

Page 86: ...n Routers are usually mounted in or on Mounting in the Cabinet Mounting on the Workbench 3 2 1 Mounting in the Cabinet The Ruijie series routers is designed with 19 inch standard cabinet Use the suppl...

Page 87: ...lation Manual Chapter 3 Installing Router 3 3 RSR20 04 RSR20 14 RSR20 18 can be mounting on the cabinet using the shipped sunk screew and fixing accessories as shown in the following figure Hanger Mou...

Page 88: ...Chapter 3 Installing Router Installation Manual 3 4 RSR20 24 can be mounting on the cabinet using the shipped sunk screw and fixing accessories as shown in the following figure Hanger Mounting...

Page 89: ...t the bottom of the router and a room of 10cm is set aside around the router for dissipation No weight is placed on the top of the router 3 3 Installing the Power Cable and Grounding Cable Ruijie RSR...

Page 90: ...If so it means that the power cable is correctly connected 3 4 Connecting the Console Ruijie series routers supply an EIA TIA 232 configuration console for local configuration Through this interface u...

Page 91: ...4 please operate gently The line card should be inserted gently and smoothly If you find it is difficult to push the line card do not use too strong force Instead unplug the line card and check if the...

Page 92: ...of the module to see if the correct cable has been used Observe the interface indicators of various modules to see if the module is working normally In privileged EXEC mode view interface information...

Page 93: ...he procedure with the HyperTerminal as example Run the HyperTerminal software to set up a new connection Select the serial port to connect the Console port of the network output engine Set the communi...

Page 94: ...14 RSR20 18 and RSR20 24 when the router is powered on the System indicator should be solid green when the router is working normally Whether the configuration terminal displays normally When the rou...

Page 95: ...ernet 0 1 changed state to up 00 00 00 17 LINK 5 CHANGED Interface FastEthernet 0 0 changed state to up 00 00 00 17 LINEPROTO 5 UPDOWN Line protocol on Interface FastEthernet 0 0 changed state to up 0...

Page 96: ......

Page 97: ...f the check shows everything is normal but the POWER Status indicator is still off please contact the local distributor or technical support team 5 2 Troubleshooting Configuration Faults After the rou...

Page 98: ...Chapter 5 Troubleshooting Installation Manual 5 2 Note When the console port parameters of your router are modified this may also lead to no display on the terminal...

Page 99: ...modem through the RJ45 crystal jack DB25 male converter When the asyn cable with 1 to 8 crystal jack is used use a straight netwok cable to connect the converter cable of the asyn interface module to...

Page 100: ...he DB25M interface of a terminal for instance dumb terminal through the RJ45 crystal jack DB25 female converter or to the DB9M interface through the RJ45 crystal jack DB9 female converter When the asy...

Page 101: ...es While the syn interface working under V 24 DCE mode is connected to the peer working under the V 24 DTE mode through V 24 DCE cables This applies to the V 24 DTE V 24 DCE mode of such line cards as...

Page 102: ...NMX 4HSH Back to Back mode V 35 DTE V 35 DCE cables Our company s SIC 1HS and NMX 4HSH 6 1 3 Connecting An E1 Interface 6 1 3 1 Connecting E1 CE1 of DB9F interface to Base Band Modem Through non balan...

Page 103: ...5 cable PC s DB9M serial interface 6 2 Order Information All methoned cables can be ordered in our company except for modem calbes as shown in the following table Table 6 10 Cable order information Ma...

Page 104: ...DB9M 2 BNC 75 OHM 3M Non balanced cable 8AE39 11 CAB E1 BALANCED DB9M RJ45M 120 OHM 3M Balanced cable crystal connector interface 39165 11 CAB E1 BALANCED DB9M RJ45F 120 OHM 3M Balanced cable crystal...