49
power (%) is used to set the limit power of this laser, that is to say, during the operation, the
maximum power set by the user can’t be higher than that set here and the minimum power
set by the user can’t be less than that set here, either. When a laser’s power is attenuated,
then the laser attenuation quotiety may be set
If it is only provided with the single laser, it can show the one-path
parameter.
(
3
)
Other manufacturer parameters
Machine configuration
Machine Type
: In most cases, the general engraving machine should be
selected and other types used for specific purposes.
Transmission Mode
: generally the “Belt Stepping Type” should be made
choice of. The control algorithm will be changed a little when other types are selected.
Feeding Mode
: it has single-way mode and two-way mode for option. If it is of
single-way feeding, it is unnecessary to check the coordinates. Feeding can be
conducted in the single-way mode; if it is of two-way feeding, the system will check the
maximum and minimum coordinates. The odd sequence means feeding should be done
to one direction and the even sequence means feeding done to the other direction. The
initial direction for the first time can be changed through setting the directional polarity or
modifying the plus and minus values of the feeding length.
Power-Off-Restart Delay
: it can be set to be 0~3000ms. After the power-off of
the electricity grid, the power supply of the system will not drop to 0 at once. There is a
delay during this time. The delay value set here should basically consistent with the
actual off-delay value. If the deviation of set value is larger, on the de-energizing for
continuous engraving, either the figure processed for the second time is not closed with
that before the cutoff, or it is coincided with that too much.
After the configuration parameters in the manufacturer parameters,
such as directional polarity, control mode, laser type and laser PWM
frequency, are modified, the system should be reset. Such a
modification can function upon the resetting of the system.
Enable parameters
Door Opening Protection
: If this item is enabled, then the door opening
protection must be connected to the controller, or, the machine will not run.
Whether to enable the blower
: If using wind out port to control the blower by
the graph layer parameter, this item must be enabled, or, the wind output is a signal for
other using.
Prompt
Prompt