User
’
s Manual of RDC6442G(U)-DFM-RD Control System
SHENZHEN RUIDA TECHNOLOGY
38
Push “Z/U” key to move the green block to the anticipant item, and when the green block is on
“enable” items, push “Enter” key to enable or disable the item, when enabled, the small diamonds
is green, and when disabled, the small diamonds is grey. When the green block is on the “Set
origin” item or the “Next origin” item, push the “X+-“ keys to select the value.
Pay attention to if when the green block is on the “Set origin” item, push the “X+-“ keys to select a
value, then, “Enter” key must be pushed to valid the change, or, the change is invalid.
Each item introduced as below:
Multiple Origins Enable: “Yes” or “No” can be selected. If you select “No”, the
system will use the single-origin logic. You can press the “Origin” key and set the origin,
and only this origin can become valid. If you select “Yes”, the system will use the
multiple- origin logic and the “Origin” key on the keyboard become invalid. In such a case,
the parameter of each origin must be set in the menu as follows.
Origin Enable1/2/3/4: after the multiple-origin logic is enabled, the four origins
can independently be prohibited and enabled.
Set Origin 1/2/3/4: after the multiple- origin logic is enabled, you can stop the
cursor at “Set as Origin 1/2/3/4”. Press the “Enter” key on the keyboard and the system
will take the coordinate figures of current X/Y axles as the corresponding ones to the
origin 1/2/3/4.
Next Origin: there are such five digits as 0~4 for option, which are the origins to
be used for the next figure. Origin 0 means the origin set by the “Origin” key on the panel
in the single- origin logic. 1~4 means the serial number of the origins in the multiple-
origin logic. Next origin can be modified to any one of origin 1~4, so as to control the start
location of next work (the premise is that the origin is enabled), but it can’t be modified to
origin 0.
Once the multiple- origin logic is selected and if the serial number
of the next origin is 1 and four origins are enabled, when the memory
file function is started or the processing file is uploaded into the PC
and this file selects “Take the Original Origin as current Origin”, the
work started for each time will use different origins. The rotation order
of origin is 1->2->3->4->1->2…….
8.3.7 Set Fact Para
After the “Set Fact Para” is selected and the Enter key pressed, the interface will show the specific
password to be entered when set as default parameter.
Prompt