9
The work area around the machine is at least 0.5 m on all sides; for
maintenance work it is at least 1 m; if used as passage way, it is at
least 1.2 m.
2.3
Connecting the machine
The machine is connected to a three-phase current outlet; its data
(voltage, amperage) must agree with the specifications on the type
plate of the machine.
The machine must be decommissioned until a damaged
power supply line has been repaired!
The power supply line must be regularly checked!
Check the correct rotational direction of the machine by
starting it. The machine does not start in case of wrong
rotational field!
In such a case, an electrician must change the
direction of rotation inside the mains plug.
The power supply to the machine must be fuse-
protected with 16A secured with an AC/DC sensitive
ground-fault circuit interrupter (type B).
Swivel range of hood
(tool magazine)
Swivel range of
knife protection
box