Installing the 7781CM in the Field
Deploying the 7781CM
Installing the Cable Power Tap
The CATV coaxial cable used in the field deployment must have 45 to 90 VAC power
multiplexed with the RF signal on the coaxial cable, since the 7781CM Connector B is used
for both electrical power and the RF signal.
Ruckus Wireless recommends installing a cable power tap (Antronix MGT2000-SDPE tap,
or equivalent) close to the 7781CM. Refer to the manufacturer’s instructions to mount the
cable power tap on the coaxial cable.
shows a typical cable power tap and
connection to the CM using an RG6 quad shield cable.
Figure 24.
Cable Power Tap Connection to the 7781CM Cable Modem
High Output Node
Tap
Cable Modem
Typical Cable Power Tap
Typical Cable Power Tap Connection