![Rubine RBO-IA8X-70SS User Manual Download Page 21](http://html1.mh-extra.com/html/rubine/rbo-ia8x-70ss/rbo-ia8x-70ss_user-manual_1498518021.webp)
pull open the cover of the terminal board.
To install the cable, proceed as follows:
·
Remove the wire clamp screw and the three contact screws
L-N -
·
Fasten the wires beneath the screw heads using the following color scheme :
Blue (N) Brown (L) Yellow-Green
·
Fasten the supply cable in place with the clamp and close the cover of the terminal board .
Connecting the supply cable to the mains
Install a standardized plug corresponding to the load indicated on the data plate. When connecting the cable directly to the mains, install
an omni polar circuit breaker with a minimum contact opening of 3 mm between the appliance and the mains .The omni polar circuit
breaker should be sized according to the load and should comply with current regulations (the earth wire should not be interrupted by the
circuit breaker).
The supply cable should be positioned so that it does not reach a temperature of more than 50
℃
with respect to the room
temperature ,anywhere along its length , or protected by insulation sleeping having an appropriate rating.
Before making the connection, check that:
·
The electrical safety of this appliance can only be guaranteed if the cooker is correctly and efficiently earthed ,in compliance with
regulations on electrical safety. Always ensure that the earthling is efficient; if you have any doubts call in a qualified technician to
check the system .The manufacturer declines all responsibility for damage resulting from a system which has not been earthed.
·
Before plugging the appliance into the mains ,check that the specifications indicated on the date plate (on the appliance and /or
packaging )correspond to those of the electrical mains system of your home .
·
Check that the electrical capacity of the system and sockets will support the maximum power of the appliance ,as indicated on the data
plate .If you have any doubts, call in a qualified technician.
·
If the socket and appliance plug are not compatible ,have the socket replaced with a suitable model by a qualified technician . The
latter, in particular, will also have to ensure that the cross section of the socket cables are suitable for the power absorbed by the
appliance. The use of adapters, multiple sockets and /or extensions, is not recommended. If their use cannot be avoided, remember to
use only single or multiple adapters and extensions which comply with current safety regulations .In these cases, never exceed the
maximum current capacity indicated on the single adapter or extension and the maximum power indicated on the multiple adapter .
The
plug and socket must be easily accessible.
Warranty & Service
FAQs and Troubleshooting
On no account open the appliancehousing!
Installation, maintenance and repairs may only becarriedout by a suitably qualified and competent person in strict accordance with current
national and local safety regulations.
Repairs and other work by unqualified persons could be dangerous. The manufacturer cannot be held liable for unauthorised work. Ensure
current is not supplied until after maintenance or repair work has been carried out.
Problem
Possible
cause
and
remedy
The oven does not heat up
- The oven may not be switched on. Switch the oven on.
- The clock may not be set. Set the clock.
- Check to see if the required settings have been applied.