8
F I L L C Y L I N P R O C E S S
A M T F I L L E D # # . # # K G
S
T
O
P T
O E
N
D
F I L L C Y L I N P R O C E S S
T I M E L E F T # # . # #
F I L L C Y L C O M P L E T E
A M T F I L L E D # # . # # K G
Refrigerant will be transferred from the cylinder on the
rear platform into the internal charge cylinder of the
RHS980.
The amount transferred will be displayed.
The Fill Cylinder procedure is complete when
approximately 18 lbs. of refrigerant has been
transferred. The Setup procedure allows changing the
value and is covered elsewhere in this manual.
REFRIGERANT BLENDS
The RHS980 is designed to recover, recycle and charge R134a. Take extreme
precaution to ensure that other refrigerants are not recovered into the RHS980.
A refrigerant identifier is recommended for evaluating refrigerant in the A/C
system to be serviced.
Recovering other refrigerants will contaminate the refrigerant in the RHS980
charge cylinder.
LEAK SEALERS
Many sealants and leak stop chemicals are being injected into A/C systems.
These may cause serious damage to the RHS980 if they are in the refrigerant
recovered being recycled.
Detection devices are available to check for the presence of these chemicals
and are highly recommended to protect the RHS980.
The RHS980 may be damaged which could void the warranty.
Call RTI for more information about solutions for detection of refrigerant blends
and leak sealers.