background image

 

15

V  A C U U M    P U M P    O  I  L    L  I  F E

R E M A I N I N G   # #  H O U R S

                                   
                      C O N  T  I  N U E ?

 

 

VACUUM PUMP MAINTENANCE 

Oil must be periodically changed in the vacuum pump 
to ensure continued performance. The RHS980 will 
display a reminder after every ten  hours of vacuum 
pump use. 

A drain port and fill port for the vacuum pump protrude 
through the rear wall of the RHS980 – to the left of the 
handle. A sight glass for viewing the oil level in the 
vacuum pump is located on the end of the fill port. 

Drain oil from the drain port and refill with new oil 
through the fill port. Use oil which is specially 
formulated for a vacuum pump. 

RTI Part Numbers: 

011-80004-00  One quart bottle 

360-80012-00  Case of 12 one quart bottles 

The oil level should be visible approximately  one-half 
the way up in the sight glass. 

 

COMBO FILTER MAINTENANCE 

The RHS980 combo filter must be replaced after every 
150 lbs. of refrigerant has been recovered from A/C 
systems. An alert will display when the filter life is at 
100 lbs. The RHS980 will shut down when the filter life 
is at 150 lbs. A new filter must be installed and a serial 
number entered to re-start the RHS980. 

A special routine for changing the combo filter is 
explained on Page 12. 

The document pocket on the left side of the RHS980 
can be removed to gain access to the combo filter. 
The combo filter is on the right side of the manifold as 
shown in the photo. A hex on top of the filter is 
provided to make filter removal and installation easy. 
Use an end wrench on this hex. New O-rings are 
provided with the replacement filter. 

A serial number is printed on a label attached to the 
new filter. Make a note of this number as it may not be 
visible when the filter is installed. This serial number 
must be entered to reset the 150 hour filter life routine. 

 

Order Filter Kit: 360-82133-00 

 

The RHS980 records the hours the vacuum pump 
runs. A reminder screen displays when that total 
equals 10 hours. The vacuum pump oil should be 
changed at that time. This screen displays the hours 
remaining until the reminder screen will display. Press 

START

 key to continue. 

Summary of Contents for RHS 980

Page 1: ...RHS 980 Operation Manual RTI Technologies Inc 10 Innovation Drive York Pennsylvania 17402 USA Phone 717 840 0678 Toll Free 800 468 2321 Web site www rtitech com Manual P N 035 81361 00...

Page 2: ...ou have purchased one of the finest Recovery Recycling and Charging Machines certified to SAE Standard J2788 Fill out and return the Warranty Card within 90 days to activate warranty and free lifetime...

Page 3: ...2 NOTES...

Page 4: ...Enable A C Capacity Database Default Values 12 Fill Cylinder Target Amount Minimum Vacuum Leak Level Vacuum Leak Time Hose Overcharge Amount Maintenance Options 12 Calibration Check Perform Calibratio...

Page 5: ...entry of data such as charge amount and given options such as vacuum leak test Once the necessary data has been entered the RHS980 will automatically perform the complete A C service and alert the tec...

Page 6: ...RHS980 to moisture or operate in wet areas 9 Use the RHS980 in locations with ventilation that provides at least four air changes per hour 9 Service hoses must be constructed of the proper materials a...

Page 7: ...tive procedure The alpha numeric keypad is used to enter data when prompted on the LCD screen Note The key also has U M printed on it Pressing this key will toggle the units of measure displayed on th...

Page 8: ...tion three wire grounded 14 AWG or larger extension cord of the shortest possible length R T I T E C H N O L O G I E S R H S 9 8 0 S E L E C T L A N G U A G E E N G L I S H E S P A O L F R A N A I S D...

Page 9: ...cycle and charge R134a Take extreme precaution to ensure that other refrigerants are not recovered into the RHS980 A refrigerant identifier is recommended for evaluating refrigerant in the A C system...

Page 10: ...ress YES key if a vacuum leak test is required Otherwise press NO key Press YES key if oil is to be injected into the A C system Fill the oil bottle on the side of the RHS980 with new oil Otherwise pr...

Page 11: ...o that oil can be injected if oil injection was selected previously Check the oil drain bottle to determine how much oil was removed from the A C system Open valve on new oil bottle until desired amou...

Page 12: ...eens DEFAULT VALUES MAINTENANCE OPTIONS and TOTAL CAPACITIES These four setup procedures are described below Press START key The first option is to select the language which be used to display screens...

Page 13: ...of time During this time the vacuum level will be monitored If the vacuum level decreases it s an indication that the A C system has a leak This screen prompts for the level of vacuum to be drawn Ente...

Page 14: ...the RHS980 to the vapor port of a refillable DOT cylinder Open the valve on the cylinder Press START key Refrigerant will be transferred from the RHS980 internal cylinder into the externally connecte...

Page 15: ...cate the need to go to recycle mode to eliminate the pressure This screen will display if pressure was not detected Replace the combo filter Note the serial number on the new combo filter label as it...

Page 16: ...rt will display when the filter life is at 100 lbs The RHS980 will shut down when the filter life is at 150 lbs A new filter must be installed and a serial number entered to re start the RHS980 A spec...

Page 17: ...4 New Refrigerant not included 5 Condenser Fan 6 Control Power Supply 7 Combo Filter 8 Charge Cylinder 9 Load Cell 10 Control Board 11 Oil Bottle Used 12 Oil Bottle New 13 Vacuum Pump 14 Compressor 1...

Page 18: ...17...