30
Auxiliary Power, CN3
The power supply can be conveyed to the module either through the PC/104 bus (J6 and J7) or
through the Auxiliary Power connector, CN3.
Facing the connector pins, the pinout of the Auxiliary Power connector is:
Power Supply Protection
The cpuModule has protection circuitry which helps prevent damage due to problems with the +5V
supply, such as:
•
Reversed polarity
•
Overvoltage
•
Overcurrent
The circuitry includes a user-replaceable fuse, which is located near the PC/104 bus connector. This
fuse is a:
•
2 amp Nano fuse
•
Littelfuse part number R451 002
WARNING!
If you improperly connect power, the module will almost certainly be
destroyed. Please verify power connections to the module before
applying power.
7
5
3
1
GND
-5V
GND
+5V
-12V
+12V
+5V
8
6
4
2
NOTE!
-5VDC, +12VDC and -12VDC voltages are not used by the module,
but are carried on the PC/104 bus connectors.