NOTICES, HAZARDS AND CAUTIONS

 

 

 

A-NDC series drives are BDM (Basic Drive Module), as defined in the EN 61800-3. They are sub-
assemblies  without  a  direct  function,  foreseen  to  be  integrated  in  a  more  complex  machine  or 
installation by a professional assembler, expert in the field of motor drives and in their related 
problems. Only a professional assembler can install and put in service this component. 

 

CE  marking:  Products  here  described  conform  to  2006/95/CE,  2004/108/CE  and  further 
modifications, when correctly installed and used. 

 

They  are  intended  to  drive  stepping  motors  with  two  phases,  base  step  angle  1.8  degree  and 
phase inductance between 1.0 and 12.0 mH. Use with different kind of motor is not allowed.

 

 

Protection  degree  IP00  for    A-NDC  04,  A-NDC  04.V,  A-NDC  06,  A-NDC  06.V  models:  Use  only 
inside  a  protective  enclosure  able  to  avoid  electric  shock  hazard.  Main  setting,  connector 
insertion or extraction has to be done with drive switched off.

 

 

Protection degree IP20 for A-NDC 94, A-NDC 96 and A-NDC 96.S: this means that they must be 
located  inside  a  protective  enclosure  meeting  requirements  of  standards  applicable  in  the 
specific application in which they are used. 

 

 

Settings and connector insertion or extraction has do be done at drive switched off. 

 

 

The drive generates some amount of heat. Take care of this in considering the total amount of 
heat  generated  in  the  enclosure  in  which  the  drives  are  located.  In  order  to  make  easier  air 
circulation in the drive, install the drive vertically (not turned upside down) with at least 5 cm of 
free  space  over  and  under  the  drive  and  1  cm  to  the  left  and  the  right  of  the  drive.  Do  not 
obstruct  air  gratings.    The  maximum  surrounding  air  temperature  must  be  lower  than  40  °C 
[

Maximum surrounding air temperature: 40 °C

]

 

 

Installation is allowed in local environment with pollution degree  N° 2 [

Use in Pollution degree 2 

Environment

].  Installation  in  presence  of  explosive  and/or  flammable  and/or  chemically 

aggressive  and/or  electrically  conductive  gas,  vapour  or  dust  and  installation  near  easily 
flammable or heat sensitive materials is strictly forbidden.

 

 

Use  for  safety  related  functions  is  forbidden  (EN  60204-1);  it  is  also  forbidden  any  application 
arrangement  in  which  a  driver  fault  or  failure  could  generate  an  hazardous  condition.  It  is 
forbidden to use this material in application covered from one or more EEC directive before the 
conformity to those directives has been declared.

 

 

Residual voltages: depending on supply type (assembled by user) and application conditions, a 
waiting time greater than 5 seconds after switching off could be necessary.

 

 

Scald hazard: due to the presence of some components operating at high temperature (120°C), 
wait some minutes after switching off in order to avoid scalds.

 

 

Driver could generate electromagnetic interference (both radiated and conducted) if instruction 
about installation directions are not respected (chap. 6). We remember however that compliance 
to 2004/108/CE directive has to be tested on whole machine in normal working condition.

 

 

Even  if  logic  input  and  output  signals  connections  are  optically  insulated,  dangerous  high 
voltage could appear on those connections in case of drive failure. For this reason, regarding to 
machine safety, you have to consider that a voltage equal to V

DC

 could be present at the I/O in 

case of failure.

 

 

Insulation of the drive parts is dimensioned for pollution degree N° 2 and for overvoltage class

 

II

. The drive can’t be connected to the main and it has to be power supplied by a power supply 

equipped with transformer main insulation.

 

 

Summary of Contents for A-NDC 04

Page 1: ...inimum and maximum value of nominal phase current setting 2 LOGIC INPUT AND OUTPUT SIGNALS connectors AM3 or C2 see Fig 1 7 9 and 10 All inputs and outputs are optically insulated mutually and respect...

Page 2: ...y common They can be used to connect the shield of logic signal cable if that is mandatory or useful depending on type of control system STEP DIRECTION and CURRENT OFF simplified input structure DRIVE...

Page 3: ...terminal B 16 Motor winding terminal A 17 Motor winding terminal A 18 Connection point for shield of motor shielded cable 4 MAIN SETTINGS Dip switches and jumpers Main setting must be done by the user...

Page 4: ...ations Smoothing effect of B type depends on resolution setting the more resolution is low the more smoothing is effective C type current profile performs higher motor torque D type current profile is...

Page 5: ...der to comply to directive 2004 108 CE and related standards EN 61800 3 installation has to be done according to schematics in Fig 7 and following indications Locate drives power supply transformer an...

Page 6: ...e right of the drive Do not obstruct air gratings The maximum surrounding air temperature must be lower than 40 C Maximum surrounding air temperature 40 C Installation is allowed in local environment...

Page 7: ...nsformer power 4 Fuse F2 type LP CC 8 by COOPER BUSSMAN LCC or equivalent Fuse F2 is mandatory for UL compliance 5 Rectifier bridge type according transformer power 6 Terminals 1 10 12 13 and 18 are i...

Page 8: ...ACKET sold separately L bracket suitable for vertical rail mounting of A NDC 04 A NDC 04 V A NDC 06 and A NDC 06 V KSM01 DIN A KIT BRACKET sold separately L bracket with plastic elements PHOENIX UM SE...

Page 9: ...from components side without heatsink Dimensions in millimeters CONNECTORS FOR A NDC 04 and A NDC 06 AM1 AMP MODU1 male 6 pole connector mod 280611 2 AM2 AMP MODU1 male 2 pole connector mod 280609 2 A...

Reviews: