8(-) ; 9(+)   DRIVER FAULT OUTPUT:

 When this output is SHORTED, drive is normally working; when it is OPEN drive 

is  in  no-working  state.  Drive  automatically  goes  in  no-working  state  when  some  protection  is  active  and 
automatically recovers when the protection resets. 

1 ; 10  

INTERNAL  GND:

  (internally  interconnected  and  connected  to  terminals  12,  13  and  18).  Galvanically 

insulated  from  logic  inputs  and  outputs  and  connected  to  power  supply  common.  They  can  be  used  to 
connect the shield of logic signal cable (if that is mandatory or useful depending on type of control system). 

 

STEP, DIRECTION and CURRENT-OFF

simplified input structure

DRIVE

GND

In+

Step Dir Coff

R1

R2

In+

680 680

1000 1000

5

7

4

3

2

6

R1 and R2 in Ohm

3.5 

 Vin 

13 Volt

<

<  

390

1200

 

 

DRIVE

Out +

9

FAULT output structure 

NOTE:
Insert a protection diode in parallel with the load 
in case of inductive load.

Vmax = 45 Volt

Imax = 50 mA

Vsat    0.8 Volt

Out -

8

 

Fig. 1 a 

 

Fig. 1 b 

 

 

Fig. 1 c: Simplified Input Scheme for A-NDC 96.S 

 

 

 

CONNECTION EXAMPLES 

NPN OUTPUT

CONTROL SYSTEM

GND

OUTPUT

VU

INPUT

+

-

 

PNP OUTPUT

CONTROL SYSTEM

GND

OUTPUT

VU

INPUT

+

-

 

Fig. 2 

Connection example with control system with NPN 

output.

 

Fig. 3 

Connection example with control system with PNP 

output.

 

 

 

 

 

Summary of Contents for A-NDC 04

Page 1: ...inimum and maximum value of nominal phase current setting 2 LOGIC INPUT AND OUTPUT SIGNALS connectors AM3 or C2 see Fig 1 7 9 and 10 All inputs and outputs are optically insulated mutually and respect...

Page 2: ...y common They can be used to connect the shield of logic signal cable if that is mandatory or useful depending on type of control system STEP DIRECTION and CURRENT OFF simplified input structure DRIVE...

Page 3: ...terminal B 16 Motor winding terminal A 17 Motor winding terminal A 18 Connection point for shield of motor shielded cable 4 MAIN SETTINGS Dip switches and jumpers Main setting must be done by the user...

Page 4: ...ations Smoothing effect of B type depends on resolution setting the more resolution is low the more smoothing is effective C type current profile performs higher motor torque D type current profile is...

Page 5: ...der to comply to directive 2004 108 CE and related standards EN 61800 3 installation has to be done according to schematics in Fig 7 and following indications Locate drives power supply transformer an...

Page 6: ...e right of the drive Do not obstruct air gratings The maximum surrounding air temperature must be lower than 40 C Maximum surrounding air temperature 40 C Installation is allowed in local environment...

Page 7: ...nsformer power 4 Fuse F2 type LP CC 8 by COOPER BUSSMAN LCC or equivalent Fuse F2 is mandatory for UL compliance 5 Rectifier bridge type according transformer power 6 Terminals 1 10 12 13 and 18 are i...

Page 8: ...ACKET sold separately L bracket suitable for vertical rail mounting of A NDC 04 A NDC 04 V A NDC 06 and A NDC 06 V KSM01 DIN A KIT BRACKET sold separately L bracket with plastic elements PHOENIX UM SE...

Page 9: ...from components side without heatsink Dimensions in millimeters CONNECTORS FOR A NDC 04 and A NDC 06 AM1 AMP MODU1 male 6 pole connector mod 280611 2 AM2 AMP MODU1 male 2 pole connector mod 280609 2 A...

Reviews: