A-NDC 04 / A-NDC 06 

A-NDC 04.V / A-NDC 06.V 

 

 

9.5

8

6

.4

9

3

.5

LED HV (green)
LED FAU (red)

AM3

AM1

AM2

86.4

LED TER (yellow)

CO

Jumpers

 

9.5

8

6

.4

9

3

.5

LED HV (green)
LED FAU (red)

AM3

CO

AM1+AM2

Jumpers

86.4

LED TER (yellow)

 

COMPONENTS LAYOUT

External measures and components layout (see from
components side without heatsink).
Dimensions in millimeters.

CONNECTORS FOR A-NDC 04 and A-NDC 06

AM1:

AMP MODU1 male 6 pole connector
m od. 280611-2

AM2:

AMP MODU1 male 2 pole connector
m od. 280609-2

AM3:

AMP MODU2 male 10 pole connector
m od. 280374-1

 

COMPONENTS LAYOUT

External measures and components layout (see from
components side without heatsink).
Dimensions in millimeters.

CONNECTORS FOR A-NDC 04.V and A-NDC 06.V

AM1 + AM2: 8 pole screw-type connector

step 3.81 mm

AM3: 10 pole screw-type connector step 2.54 mm

 

Fig. 9 a

 

Fig. 9 b

 

 

NDC

series

TER

C1

C2

 

A-NDC 94 / A-NDC 96 / A-NDC 96.S 

 

Dimensions in millimeters. 

Fig. 10

 

Summary of Contents for A-NDC 04

Page 1: ...inimum and maximum value of nominal phase current setting 2 LOGIC INPUT AND OUTPUT SIGNALS connectors AM3 or C2 see Fig 1 7 9 and 10 All inputs and outputs are optically insulated mutually and respect...

Page 2: ...y common They can be used to connect the shield of logic signal cable if that is mandatory or useful depending on type of control system STEP DIRECTION and CURRENT OFF simplified input structure DRIVE...

Page 3: ...terminal B 16 Motor winding terminal A 17 Motor winding terminal A 18 Connection point for shield of motor shielded cable 4 MAIN SETTINGS Dip switches and jumpers Main setting must be done by the user...

Page 4: ...ations Smoothing effect of B type depends on resolution setting the more resolution is low the more smoothing is effective C type current profile performs higher motor torque D type current profile is...

Page 5: ...der to comply to directive 2004 108 CE and related standards EN 61800 3 installation has to be done according to schematics in Fig 7 and following indications Locate drives power supply transformer an...

Page 6: ...e right of the drive Do not obstruct air gratings The maximum surrounding air temperature must be lower than 40 C Maximum surrounding air temperature 40 C Installation is allowed in local environment...

Page 7: ...nsformer power 4 Fuse F2 type LP CC 8 by COOPER BUSSMAN LCC or equivalent Fuse F2 is mandatory for UL compliance 5 Rectifier bridge type according transformer power 6 Terminals 1 10 12 13 and 18 are i...

Page 8: ...ACKET sold separately L bracket suitable for vertical rail mounting of A NDC 04 A NDC 04 V A NDC 06 and A NDC 06 V KSM01 DIN A KIT BRACKET sold separately L bracket with plastic elements PHOENIX UM SE...

Page 9: ...from components side without heatsink Dimensions in millimeters CONNECTORS FOR A NDC 04 and A NDC 06 AM1 AMP MODU1 male 6 pole connector mod 280611 2 AM2 AMP MODU1 male 2 pole connector mod 280609 2 A...

Reviews: