background image

2

Notices 

CoPyRIghT

 (Copyright © 2010 Inverto Digital Labs )

Not to be copied, used or translated in part or whole without Inverto prior consent in writing except approval of 

ownership of copyright and copyright law.

WaRRaNTy

This warranty does not cover parts which may become defective due to misuse of the information contained in 

this manual.

Read this manual carefully and make sure you understand the instructions provided. For your safety, be aware of 

the following precautions.

WaRNINg!  IMPoRTaNT SafeTy INSTRUCTIoNS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).  NO 

USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

 

WaRNINg

To

•   reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

To avoid explosion danger, do not dispose of batteries in an open fire.

• 

Ce MaRK foR eURoPeaN haRMoNISeD STaNDaRDS

The CE mark which is attached to these products means it conforms to EMC Directive (89/336/EEC) and 

Low Voltage Directive (73/23/EEC).

IMPoRTaNT INfoRMaTIoN

Please retain the original packaging, should it be necessary at some stage to return the unit.

Disposal of Old Electrical and Electronic Equipment (Applicable in the European Union and other European 

countries with separate collection systems)

This symbol on the product or on its packaging indicates that this product shall not be treated as household waste.  

Instead  it  shall  be  handed  over  to  the  applicable  collection  point  for  the  recycling  of  electrical  and  electronic 

equipment.  By ensuring this product is disposed of correctly, you will help prevent potential negative consequences 

for the environment and human health, which could otherwise be caused by inappropriate waste handling of this 

product.  The recycling of materials will help to conserve natural resources.  For more detailed information about 

recycling of this product, please contact your local Civic Office, your household waste disposal service, or the shop 

where you purchased the product.

CoPyRIghTS

Television  programmes,  movies,  video  tapes,  discs,  and  other  materials  may  be  copyrighted.    Unauthorized 

recording of copyrighted material may be against the copyright laws in your region.  Also, use of this product with 

cable television transmissions may require authorization from the cable television operator or transmitter/owner.

VeNTILaTIoN

Do not expose the product to high temperatures, such as placing it on top of other product that produce heat or 

• 

in places exposed to direct sunlight or spot lights.

The ventilation slots on top of the product must be left uncovered to allow proper airflow into the unit. 

• 

Do not stand the product on soft furnishings or carpets. 

• 

Do not stack electronic equipments on top of the product.

• 

Do not place the product in a location subject to extreme changes in temperature. The temperature gradient 

• 

should be less than 10 degrees C/hour.

Place the product in a location with adequate ventilation to prevent the build-up of heat inside the product.  The 

• 

minimum ventilation space around the unit should be 7 cm. The ventilation should not be impeded by covering 

the ventilation openings with items, such as newspapers, table cloth, curtains, etc.

PoWeR SoURCeS

The product is not disconnected from the AC power source (mains) as long as it is connected to the power outlet 

• 

or wall socket, even if the product is turned off.

If the product will not be used for a long period of time, disconnect it from the AC power outlet or wall socket.

• 

Summary of Contents for IDLV-4000P-30x

Page 1: ...IDLV 4000P Professional Integrated Receiver Decoder and TS Processor...

Page 2: ......

Page 3: ...En Professional Integrated Receiver Decoder and TS Processor User Manual IDLV 4000P...

Page 4: ......

Page 5: ...iagram 5 Accessories 5 Control Panels and Interfaces 6 Menu structure and operations 8 Remote management and control over web interface 16 Remote management and control over HDMS 24 Technical Specific...

Page 6: ...he environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed inf...

Page 7: ...it is essential that both operating and servicing personnel follow generally accepted safety procedures in addition to the safety precautions specified in this manual Whenever it is likely that safet...

Page 8: ...Multiple inputs DVB S2 S C T TS IP ASI DS3 optional SD MPEG 2 MP ML digital Video decoding Digital audio embedded in SDI output Multiple Analog and Digital Outputs ASI CVBS YPbPr SD SDI AES EBU TS IP...

Page 9: ...he IDLV 4000P You can set it as IP In or IP Out which is exclusive to each other refer to section Optional Function Filter under System The Mux Filter function block is standard option and could be co...

Page 10: ...can be adjusted Operation buttons ENTER EXIT buttons are used to up down pages of menu or increase decrease value when editing values are used to move cursor ENTER is used to enter sub menu or confirm...

Page 11: ...on IDLV 4000P 30x Light B9 B19 ASI1 output interface 75 ohm female BNC connector B17 ASI input interface 75 ohm female BNC connector B10 RS 232 interface B11 Tuner Loop Out interface B12 Tuner In inte...

Page 12: ...P Address for LAN access If no message is presented or there is no light on the display the device is defective and has to be returned for servicing Note The local IP address and unit name can be chan...

Page 13: ...xxT model Frequency Enter the proper frequency of the COFDM signal in MHz Bandwidth Set the bandwidth from 6M 7M 8M QAM This menu only is shown on IDLV 4000P xxC model Constellation Enter the modulat...

Page 14: ...n which signal the encrypted program carries The Tuner Lock green LED should be on when CAM is inserted There are 2 submenus CI Source and Setup which allow you to set or select the parameters of the...

Page 15: ...ill turn on the caption VBI Mode Select DISABLE will disable the VBI mode and select ENABLE will enable the VBI mode Audio You can configure the audio settings in the submenu Audio Level Use the keys...

Page 16: ...TS IP input C xxxxx the program comes from the internal CI function block xxxxx is the program name On Mux List sub menu which is on the first row all encrypted programs are labeled with a sign All p...

Page 17: ...S note the Mux TS is showed only when the Mux Filter function block is enabled and turned on The Mux TS indicates not only the after multiplexed TS when Mux is enabled but also the after filtered TS w...

Page 18: ...could be switched On Off independently The default value is off To activate the channel you need to set the switch to be on x Program It shows all programs carried by the transport stream from the sou...

Page 19: ...ll the user configurable parameters will be set to the factory default settings including IP address and the unit name Note the unit will not be connected with the HDMS remote management system until...

Page 20: ...isplayed The default user name is root and password is 12345 If you forget this username and password you can use the front panel button to change it You can set it in System HTTP login menu The param...

Page 21: ...En 17 Input Use this page to set parameters for the tuner input Click Apply button to submit or click Cancel button to cancel...

Page 22: ...h the display with the latest status of settings or click the Cancel button to cancel Set parameters for ASI2 SDI output port Select SDI under Mode in order to set the ASI2 SDI port as SDI output port...

Page 23: ...n to submit Refresh button to refresh latest status of settings or click Cancel button to cancel Set detail parameters for decoded programs Click on the Apply button to submit Refresh button to refres...

Page 24: ...20...

Page 25: ...CI Configure the parameters for the CI slots Click Apply button to submit or click Cancel button to cancel IP In Out Set parameters for IP IN Click Apply button to submit or click Cancel button to ca...

Page 26: ...22 Set parameters for IP OUT Click Apply button to submit or click Cancel button to cancel...

Page 27: ...En 23 System Set parameters for system Click Apply button to submit or click Cancel button to cancel...

Page 28: ...P xx units automatically Devices that are found will be displayed in the Devices Window in HDMS When a new IDLV 4000P xx is added to the remote control network you can press to refresh the network The...

Page 29: ...ovides Alarms management Devices management and User accounts management It may also be necessary to modify some of the other settings to suit the particular installation Please refer to the HDMS Refe...

Page 30: ...pe female 75 for Input 1 x F type female 75 for loop through output Input frequency range 104 862MHz VHF UHF Input level 20 70dBm Quasi Error Free QEF Constellation DVB T QPSK 16 QAM 64 QAM DVB T2 QPS...

Page 31: ...ifferential Phase 2 Signal to Noise Ratio 55 dB luminance weighted Analog Audio Output Connector type XLR Male Socket Output Impedance 600 balanced Output mode Left Right Dual Mono Stereo Number of Ou...

Page 32: ...the quality of receiving DVB S2 S signal Ethernet This menu only is shown on IDLV 4000P 44x 42x models which set TS IP streaming board as IP IN Stream IP Addr 16 16 16 16 Stream Netmask 255 255 255 0...

Page 33: ...C addresses Gateway Mac address ff ff ff ff ff ff Protocol UDP TS Pkts per UDP 7 Time to Live 255 Type of Service Normal Source ASI Input Mode DVB Uni Multicast Setup Multicast IP 225 1 1 1 Multicast...

Page 34: ...tenderly IDLV 5100P Professional Multi format SD HD Integrated Receiver Decoder Enter Exit Power Tuner Lock Alarm Avoid eroding If the device is connected well with power and cables but the picture is...

Page 35: ...party Any liability of the Company or its supplier which is not excluded shall be limited to the purchase price of the Product Some jurisdictions do not allow the limitation of incidental or conseque...

Page 36: ...specialist dealer or the point of sale Warrantee claims cannot be made directly to the company Inverto Digital Labs You should therefore keep your sales receipt as proof of purchase The Company recom...

Page 37: ...En 33...

Page 38: ...V151111...

Reviews: