Each IDLV-4000P-xx has an IP address, a network sub mask and a gateway.
These parameters must be set to appropriate values so that the unit can be
accessed by the remote control system (for example: HDMS).
IP Address:
The IP address for the unit.
Network Mask: The network mask for the subnet to which the unit is connected.
Gateway:
The gateway for the network to which this unit is connected.
Trap IP
The IDLV-4000P provides a Monitor Center IP address. You can set this to be
the same IP address of the Monitor Center, which is typically a PC in order to
allow the device to send messages to the monitor center.
Unit Name
The IDLV-4000P allows you to edit the unit name which is displayed on the front
panel LCD. Default name is ‘Digital TV Processor”. The unit name should be
within 20 characters in ASCII format.
Properties
MAC address:
Factory-set MAC address is guaranteed to be unique. You can-
not configure this address.
FW Version:
the version of the FPGA software (note that this version number
will be changed automatically according to the TS/IP settings (‘IP In’ or ‘IP Out’).
SW Version:
the version of the main software.
Factory
Settings
All the user configurable parameters will be set to the factory default settings,
including IP address and the unit name. Note the unit will not be connected with
the HDMS remote management system until the IP is properly configured.
O p t i o n a l
Function
External Board Type:
Press the <ENTER>-key to activate the menu, and use
the <↑> <↓>-keys to configure the TS/IP functional block to ‘IP In’, ‘IP Out’ or ‘No
Exist’. Press the <ENTER>-key to confirm and save or press the <EXIT>-key to
discard and exit.
After the operation is complete, you need reboot the unit to valid the configura
-
tion.
IP In:
The TS/IP port is configured as input. You can feed transport stream over
IP into the unit. The menu ‘Ethernet’ will be shown under the inputs menu.
IP Out:
The TS/IP port is configured as output. You can set the transport stream
over IP output to the IP network. The menu ‘Ethernet’ will be shown under the
outputs menu.
No Exist:
The TS/IP port is invalid. Therefore, the menu ‘Ethernet’ will not be
shown anywhere.
Filter Function:
Press the <ENTER>-key to activate the menu, and use the <↑>
<↓>-keys to enable MUX or Filter function. When enable this function, there will
be relative menu appearing in Output menu.
HTTP Login
Modify the username and password for the WEB management.
The default username:
root
The default password:
12345
Machine Type Reserved for factory operation, not open to customer.
Summary of Contents for IDLV-4000P-30x
Page 1: ...IDLV 4000P Professional Integrated Receiver Decoder and TS Processor...
Page 2: ......
Page 3: ...En Professional Integrated Receiver Decoder and TS Processor User Manual IDLV 4000P...
Page 4: ......
Page 24: ...20...
Page 26: ...22 Set parameters for IP OUT Click Apply button to submit or click Cancel button to cancel...
Page 37: ...En 33...
Page 38: ...V151111...