97
Metering
Metering
B.
SRC (source)
This selects the source for the analyzer.
C.
WINDOW
Here you can move the analyzer’s vertical display region in a
range of 0 dB – -48 dB.
D.
AVG (average)
Here you can select the averaging method for the analyzer.
E.
AVG TIMES (average time)
This specifies the value (1–128) by which the analyzer’s
display will be averaged.
F.
PEAK HOLD button
When this is on, the analyzer’s peaks will be held.
The Hold time is specified by the HOLD TIME setting of the
METER SETUP popup.
7.
Use SRC to select the source for the analyzer.
• If the analyzer display is too large or too small, use WINDOW
to adjust the vertical display area.
• As desired, use AVG and AVG TIMES to make settings for
averaging.
If an input channel is selected, its direct out will be the source
for the analyzer.
If an output channel is selected, its output will be the source for
the analyzer.
If you select MONITOR L or MONITOR R, you can use [SOLO]
to conveniently switch the channel that’s being sent to the
analyzer.
fig.ScrMeterList_Guide.eps
1.
Name list
This lists the names of each channel and group.
FIG.List_Compo_Guide.eps
•Name
This is the name of the channel or group. If you move the
cursor to the name of a channel, that channel will become the
selected channel.
•Link indication
This indicates the link status of the channel.To change the
link status of a channel, move the cursor to the name of the
desired channel, and press [F5 (LINK)] to turn link on/off.
In the NAME LIST tab, the function buttons perform the following
tasks.
*1 This is unavailable if the cursor is at MAIN L, MAIN R, DCA1–8, or
MUTE1–8.
*2 This is unavailable if the cursor is at DCA1–8 or MUTE1–8.
AVG value
Explanation
OFF
Averaging will not be performed.
NRM
Averages evenly by the number specified in
AVG TIMES.
EXP
Recent times will be weighted more heavily in
the calculation.
If the M-380 and M-380RCS (software that remotely controls the
M-380 from a PC) attempt to display the analyzer
simultaneously, display on the M-380 will take priority. In this
case, the analyzer levels will not be shown in the M-380RCS
window.
fig.RCSOccupyRTA.eps
Listing the channel names
and group names
NAME LIST tab
Button
Operation
[F1 (METER)]
Displays the METER tab, which shows the
levels of all channels.
[F2 (LAYER VIEW)]
Displays the LAYER VIEW tab, which shows
the levels of the channels in the currently se-
lected channel layer.
[F3 (Analyzer)]
Displays the Analyzer tab, which shows the
31-band realtime analyzer.
[F4 (NAME LIST)]
Displays the NAME LIST tab, which lists the
channel names and group names.
[F5 (LINK)]
*1
Turns link on/off for the channel at the cur-
sor location.
[F6 (NAME EDIT)]
Accesses the NAME EDIT popup, where you
can edit the name at the cursor location.
[F7 (COPY)]
*2
Accesses the COPY popup, with the channel
at the cursor location as the copy-source.
1
1
Name Link indication
M-380_e1.book 97 ページ 2010年6月30日 水曜日 午前10時31分