185
Management of the M-48 live personal mixer
Management of the M-48 live personal mixer
2.
LINE OUT
As the LINE OUT source, you can choose either PHONES (the
signal immediately before PHONES VOLUME), MAIN bus, or
AUX bus. This is used for a floor monitor or for two-channel
recording. Since a low-pass filter is provided on LINE OUT, it
can also be used to output just the low-frequency range to a
floor monitor or tactile transducer.
The M-48 has 16 memories, and allows mixer settings to be stored or
recalled.
Memories 1–16 can be manipulated from the M-48 itself or from the
M-380 or PC.
fig.V-Mix_M48.eps
Use the REAC B port to connect M-48 units to the M-380. A
separately available S-4000D splitter and power distributor is
required in order to connect M-48 units.
The output from the M-380’s REAC B port is distributed via the S-
4000D. You can connect up to four S-4000D units serially and
support up to twenty-four
M-48 units.
The mixing engineer can make settings for each M-48 unit from the
M-380.
If an M-48 unit is connected to the M-380’s REAC A port or
SPLIT/BACKUP port, it will not be possible to set or manage
the M-48 from the M-380.
Here are some examples of connecting M-48 units to an M-380 that is
being used as an FOH console or as a monitor console.
fig.M48ConnectExs.eps
fig.M48ConnectExs.eps
Memory functionality
Connecting M-48 units to
the M-380
REAC B
MASTER
SLAVE
S-1608
POWER
POWER
POWER
M-380
S-4000D
M-48
M-48
M-48
(SPLIT)
(SPLIT)
(SPLIT)
Connection examples
Connect M-48 units to the M-380
(setup as the FOH console)
FOH CONSOLE
SLAVE
SLAVE
S-1608
S-4000S
S-4000D
(SPLIT)
M-48
M-48
M-48
(SPLIT)
(SPLIT)
Connect M-48 units to the M-380
(setup as the monitor console)
FOH CONSOLE
MONITOR CONSOLE
SLAVE
S-1608
S-4000D
SLAVE
SLAVE
S-1608
S-1608
(SPLIT)
M-48
M-48
M-48
(SPLIT)
(SPLIT)
M-380_e1.book 185 ページ 2010年6月30日 水曜日 午前10時31分