M0619-1 ver 2.6
35
4.5 Replacement of wear parts
4.5.1 Replacement of air sealings
4.5.2 Replacement of signal pins (TC250-8E only)
Replace a signal pin when the spring jams, or become bent.
Action
Note
1
Remove air sealings
Remove the air sealings with a screw driver.
NOTE!
There are totally 8 air sealings.
2
Clean sealing holes
Wipe clean the sealing holes. Remove all
remaining parts of the sealings.
3
Mount air sealings
Tap in the new air sealings with a plastic
mallet.
Action
Note
1
Power off
Switch the power off and lock the circuit
breaker.
2
Remove signal pins
Pull out the signal pins with a pair of pliers.
NOTE!
There are totally 20 signal pins.
3
Replace signal pins
Fit the new signal pins by pushing them into
the sleeves.
NOTE!
The signal pins must be individually
pressed fully into the sleeves using a small
screw driver!
4
Power on
Unlock the circuit breaker and switch the power
on.