M0001-1 version 2.0
35
5 MAINTENANCE AND SERVICE
5.1 Maintenance chart
The valve units must be maintained regularly to ensure proper function. The specified intervals
are approximate and valid under normal conditions. Under extreme conditions, such as dirty
environments or extreme robot movements, the intervals should be shortened. Consider the
table as a guide and update as the production experience of each system increases.
NOTE!
Valve units must only be dismantled and repaired by Robot System Products
during the warranty period. Otherwise, the warranty will not be valid.
5.1.1 Recommended tools for maintenance
Tools
Applications
Complete set of Allen keys
For dismounting and mounting.
Torque wrench
For all socket head cap screws
5.1.2 Activities and intervals
Maintenance
activity
Equipment
Interval
Description
Inspection
Valve unit
2 weeks
Visual inspection of Valve unit.
5.2 Visual inspection of valve unit
Visually check the following:
Check
Note
Cables to Valve unit
Not damaged or dirty
Hose to Valve unit
Not damaged or dirty
Hoses from Valve unit
Not damaged or dirty
All parts
No wear, not damaged or dirty
Summary of Contents for P0010A
Page 2: ...2 M0001 1 version 2 0 ...
Page 16: ...16 M0001 1 version 2 0 2 2 1 Pne0214 010 for small valve unit P0010A ...
Page 17: ...M0001 1 version 2 0 17 2 2 2 Pne0214 011 for small valve unit P0011A ...
Page 18: ...18 M0001 1 version 2 0 2 2 3 Pne0214 008 for small valve unit P1008 ...
Page 19: ...M0001 1 version 2 0 19 2 2 4 Pne0214 013 for small valve units P0012A and P0013A ...
Page 20: ...20 M0001 1 version 2 0 2 2 5 Pne0214 026 for extended valve unit P0026 ...
Page 21: ...M0001 1 version 2 0 21 2 2 6 Pne0214 027 for extended valve units P0027 P0028 and P0029 ...
Page 22: ...22 M0001 1 version 2 0 2 2 7 Pne0214 035 for extended valve units P0035 and P0036 ...
Page 23: ...M0001 1 version 2 0 23 2 2 8 Pne0214 037 for extended valve unit P0037 ...
Page 24: ...24 M0001 1 version 2 0 2 3 Internal circuit diagrams 2 3 1 E0214 167 for small valve units ...
Page 25: ...M0001 1 version 2 0 25 2 3 2 E0214 222 for extended small valve units ...
Page 28: ...28 M0001 1 version 2 0 3 3 Circuit diagram E0214 306 for sensor interface P1033 ...
Page 29: ...M0001 1 version 2 0 29 3 4 Circuit diagram E0214 263 for sensor interface P1018 and P1032 ...
Page 43: ...M0001 1 version 2 0 43 ...
Page 44: ...44 M0001 1 version 2 0 ...