Category Rating Brief Description
Typical Applications
CAT II
Single phase
receptacles
and connected loads
• Household appliances, power tools
• Outlets more than 30ft(10m)from a Cat
III source
• Outlets more than 60ft(20m)from a Cat
IV source
CAT III
Three phase circuits
and single phase
lighting circuits in
commercial buildings
• Equipment in fixed installations such
as 3-phase motors, switchgear and
distribution panels
• Lighting circuits in commercial buildings
• Feeder lines in industrial plants
• Any device or branch circuit that is close
to a Cat III source
CAT IV
Connection point
to utility power and
outdoor conductors
• Primary distribution panels
• Overhead or underground lines to
detached buildings
• Incoming service entrance from utility
• Outdoor pumps
Function
Maximum Input
Voltage AC or DC
600V AC/DC
Resistance, Continuity, Diode Test
600V AC/DC
Frequency, Duty Cycle
600V AC/DC
μA, mA Current AC or DC
200mA/600V fast acting Resettable Fuse
02/12/2017 Version No. 001
3-Safety Category Ratings
6-General Specifications
4-Input Limits
02/12/2017 Version No. 001
The measurement category(CAT)rating and voltage rating is determined by a combination
of the meter, test probes and any accessories connected to the meter and test probes.
The combination rating is the LOWEST of any individual component.
WARNING:
Operation is limited to CAT II applications when the insulated tips are removed
from one or both test probes. Refer to Input Limits section in this manual for maximum
voltage ratings.
5-Meter Description
1-Non-contact voltage detector
2-Non-contact voltage indicator
3-LCD display
4-MODE button
5-Rotary function
6-Hz/% Duty Cycle switch
7-Flashlight/Backlight button
8-Flashlight button
9-Test leads
1
3
4
2
5
6
7
8
9
Insulation
Class 2, Double Insulation
Diode Test
Test current 1mA max., open circuit voltage of 1.5V typical
Continuity Test
Audible signal if the resistance is <100Ω
Low Battery Indication
“
”is displayed
Display
4000 count LCD
Over Range Indication
“OL” is displayed
Polarity
Minus symbol “-“ is displayed for negative polarity
Measurement Rate
3 readings per second, nominal
Auto Power Off
After approx. 30 minutes
Input Impedance
>7.5MΩ AC and DC Voltage
AC Response
Average Responding
AC Bandwidth
50 to 60Hz
Batteries
Two AAA 1.5V batteries
Fuse
μA, mA Ranges: 200mA/600V fast acting Resettable Fuse
Operating Environment
32°F to 104°F(0°C to 40°C)at <70% relative humidity
Storage Environment
14°F to 122°F(-10°C to 50°C)at <80% relative humidity
Operating Altitude
2000 meters
Dimensions/Weight
4.6”x 2.3” x 1.4”/0.32lb(116 x 59 x 36mm/145g)
Safety
Complies with UL 61010-1 v.3 for measurement
Category lV 600V, Polution Degree 2