APPENDIX
13/10/2016 Version No. 001
55
Parallel
Regulation
Line:
≤ 0.01% + 3mV
Load:
≤ 0.01% + 3mV
(rating current ≤ 3A)
Load:
≤ 0.02% + 5mV
(rating current > 3A)
Series
Regulation
Line: ≤ 0.01% + 5mV
Load:
≤ 100mV
Meter
Resolution
Voltage
10mV or 100mV
current
1mA or 10mA
2mA or 10mA (RPE-1326)
Display
LCD
4.3" single color LCD display
Ammeter
3.200A full scale, 4 digits or 3 digits
6.200A full scale, 4 digits or 3digits
(RPE-1326)
Voltmeter
33.00V full scale, 4 digits or 3 digits
Accuracy
Setting/
Read back
Accuracy
Voltage: ± (0.1% of r 30mV)(4digits)
± (0.1% of r 200mV)(3digits)
Current: ± (0.3% of r 6mA)(4digits)
± (0.3% of r 20mA)(3digits)
(RPE-1326) ± (0.3% of r 10mA)(4digits)
(RPE-1326) ± (0.3% of r 20mA)(3digits)
CH3 on the
GDE-3323
Output Voltage
5V, ±5%
Output Current
5A
Line
≤ 3mV
Load
≤ 10mV
Ripple & Noise
≤ 2mVrms (5Hz ~ 1MHz)