Switch GREEN
 Sensor

AC, DC, or DCC trains can be  controlled.

Make sure to program the YardMaster for the desired time delay.
Program a lap count if desired.

When the power supply is turned on the train should run. If it does not then press the
Alternate button. This is a one-time operation since the YardMaster will remember the switch state in
memory.

Change direction of the train as desired. The YardMaster will operate in both directions.

Adding a signal light is optional, but adds to the fun.

For gradual decelerations and accelerations consider using a StationMaster for a station stop

.

Station Stop Hookup Diagram for a Remote Track Section

Place MAGNET
on bottom of engine.

Track power provides 
power to YardMaster

Isolators, 2 places

Station Stop with Sensors

Train 
Sensor

Attach
to 
Track

 RRConcepts.com

1

2

3

4

5

6

20

19

18

17

16

15

7

11

8

12

9

13

14

Parts List

YardMaster          1
Track Isolators     2
Train Sensor        1
Train magnet       1
wire as required

This is basically the same hookup as a standard station stop in a loop
however it uses the track power as the voltage input to the YardMaster.
Add this to a remote location on your railroad without stringing wires to the
remote section.  Trains can run in either direction  Track power must be 8 volts or more.. 

The sensor provides an exact stopping location. A train magnet is required.

Summary of Contents for YardMaster-5

Page 1: ...o Detachable screw down terminal blocks allow quick disconnect for long term storage keeping all wires in place ONLY ATTACH WIRES WHILE THE POWER IS OFF YardMaster 5 Turnout Track switch Controller La...

Page 2: ...ht connections 8 Factory Reset 9 Operating Modes 10 Time Delay 11 ID number 12 Laps 13 Forced Alternate 14 Auxiliary Relay Module 15 STOP GO Relay Modue Descriptions 16 Block Control 17 Station Stop 1...

Page 3: ...Switch GREEN relay Terminals and Switch RED will cause the Common Relay Terminals to connect to the Switch RED Terminals The TURNOUT will also fire in synchronization and the lamps outputs will change...

Page 4: ...The connecting plugs are keyed for correct orientation The tab on the plug will be on the top when attached correctly If the center wire is cut the StationMaster will only provide power to the YardMa...

Page 5: ...voltage Except for the 5 volt LED output which is constant ALSO IMPORTANT When turnouts are attached the AMPERAGE must be sufficient to power them without a voltage drop which would reset the YadMast...

Page 6: ...le a 12VAC input will provide approximately 16VDC turnout voltage etc If a short circuit condition is present on these terminals the YardMaster will blink the BLUE LEDs when energized After a delay th...

Page 7: ...to terminal 18 Terminal 4 will internally connect to terminal 17 The Alternate sensor or alternate pushbutton will alternate these contacts Since this is a simple relay there are no polarity or voltag...

Page 8: ...feature can be turned off if needed by programming a different operating mode If direct driving LED s use pin 14 as the constant 5 volt voltage source and wire as shown for either separate LEDs or a...

Page 9: ...seconds YardMaster will slowly flash the blue sensor LED many times but keep holding down the button After a delay the blue status LED will twinkle to indicate a factory reset Release the button Facto...

Page 10: ...is the default setting after a factory reset 2 Control SLOW_MOTION turnouts electric switches These include Tortoise Aristocraft slow motion etc 3 Synchronize Auxiliary relay to internal relay Can not...

Page 11: ...time delay will not be operational when attached to a StationMaster 2 To clear the time delay either program for 1 blink or perform a factory reset Programming a Time Delay Used for Station stops Reve...

Page 12: ...ogram as YardMaster 4 4 IDs are possible to allow 4 YardMasters to be wired together 3 Quickly press the ALTERNATE pushbutton to exit programming mode Notes 1 Unless programmed for an ID other than 1...

Page 13: ...3 blinks 3 laps 4 blinks 4 laps 3 Quickly press the ALTERNATE pushbutton to exit programming mode Notes 1 The lap counter will not function when attached to a StationMaster 2 When attached to a Stati...

Page 14: ...sor is hit For example when the Switch RED sensor is hit the Alternate sensor will always switch to GREEN regardless of the number of times it is hit This allows the turnout to be set correctly for op...

Page 15: ...ndle A very quick burst of voltage is given to the switch motor which prevents overheating and operates without the need for capacitive discharge units When the YardMaster is programmed for blink 3 th...

Page 16: ...etected When an ALTERNATE sensor is triggered the relay will energize for the programmed time delay and then the alternate function will occur This allows a time delay station stop When the FORCE RED...

Page 17: ...ith the switch GREEN sensor location to obtain the desired results The signal light is optional but adds to the fun Switch Green Sensor Switch RED Sensor Green Terminal Optional Signal Light Block Con...

Page 18: ...nate button This is a one time operation since the YardMaster will remember the switch state in memory Change the direction of the train as required The YardMaster will operate in both directions Addi...

Page 19: ...one time operation since the YardMaster will remember the switch state in memory Change direction of the train as required The YardMaster will operate in both directions Terminals 3 4 connect to the A...

Page 20: ...to GREEN The train will stop After the programmed time delay the YardMaster will switch to RED and the train will run again Change direction of the train as required The YardMaster will operate in bo...

Page 21: ...celerations consider using a StationMaster for a station stop DC trains only Station Stop Hookup Diagram for a Remote Track Section Track power provides power to YardMaster This is basically the same...

Page 22: ...aster for a station stop Station Stop Hookup Diagram for a Remote Track Section Place MAGNET on bottom of engine Track power provides power to YardMaster Isolators 2 places Station Stop with Sensors T...

Page 23: ...ce the points to the correct orientation not shown Magnets are not offset but placed as normal As the train passes over a sensor the turnout aligns to the proper orientation The Smart Turnout works fo...

Page 24: ...on the same track The Alternating Path hookup will work for ALL trains Electric Battery and Live Steam See power hookup page for input power requirements For more fun the YardMaster can directly driv...

Page 25: ...ggered the YardMaster will return to the Switch RED state and turn off the signal light Whatever power is applied to terminals 3 and 4 will be switched to terminals 19 and 20 when the YardMaster is GR...

Page 26: ...or DC up to 110V Be careful The graphics on the module show the terminal connections Pin 1 Normally open pole 1 Pin 2 Switching pole 1 switches between 1 and 3 Pin 3 Normally closed pole 1 Pin 4 Norm...

Page 27: ...irections both turnouts must be powered The YardMaster will switch when the train is clear of the sensor This will prevent the train from parking on the sensor The sensors have no polarity See the pow...

Page 28: ...t the train from parking on the sensor The sensors have no polarity See the power page for input power requirements If acceleration and deceleration is desired DC trains only consider using a StationM...

Page 29: ...instead of this hookup It is also a much easer hookup Enhancement Ideas 1 Program a lap count for each train to do multiple laps before switching 2 Add a signal light 1 2 3 4 5 6 20 19 18 17 16 15 7...

Page 30: ...t Pin 19 is connected to pin 18 and these two are connected to the other DC transformer output Pins 8 and 9 are shorted together This tells the YardMaster to perform automatic switching using a progra...

Page 31: ...ck and forth Automatic Reversing with in between station stops Diode with insulated rail connector One on each side RRConcepts com Red wire this end Attach relay cable between relay and YardMaster Add...

Page 32: ...g diode Required Slow down diodes optional Slow down diodes optional To YardMaster Stopping block Stopping block Slowing block Slowing block Full speed block Alternatively diodes can be added directly...

Page 33: ...Attach relay cable between relay and YardMaster Add additional sensors in parallel for additional stops STOP GO RELAY MODULE SIDING SELECTION RELAY MODULE Program for Single Siding blink 7 Jumper bet...

Page 34: ...n station stops OPTION No track modifications RRConcepts com No jumper When it is not desirable to add diodes to the track for end of track sensing an alternative is to add sensors as shown Sensors ar...

Page 35: ...al terms PORT IS POSITIVE For LGB style trains the left rail is always POSITIVE while the right rail is NEGATIVE Notice that this is reversed for trains following NMRA standards such as HO N etc and t...

Page 36: ...ED and GREEN buttons on the YardMaster Swap the wires in the turnouts as necessary to make this happen Notice that the sensors must be 100 reliable or a short circuit will occur For some commercial ap...

Page 37: ...A voltmeter could be used to test this left rail is positive for G scale or quickly place a train on the track to see which way it wants to go but don t let it enter the loop yet Reverse the wires to...

Page 38: ...ns of the trains are as shown For large scale trains in nautical terms PORT IS POSITIVE For LGB style trains the left rail is always POSITIVE while the right rail is NEGATIVE Notice that this is rever...

Page 39: ...en a sensor is triggered track power will switch to the other loop of track Note differences in terminals 3 4 5 and 6 between AC trains and DC trains AC trains generate electrical noise which affect t...

Page 40: ...g RED or GREEN a time delay is in process When flashing RED BLUE and then GREEN BLUE the YardMaster is self running due to the RED sensor terminals closed on power up STATUS LED Sensor LED LED indicat...

Page 41: ...gnet offset to the right and freight trains have the magnet offset to the left side Sensor placement for HO EZ track is under the roadbed Other scale trains can place the sensors where appropriate Ver...

Reviews: