6
StationMaster Basic Hookup Description
The StationMaster is designed to be installed
between the train transformer, and the track.
Attach 1 & 2 to your transformer's DC output (Sometimes
labeled as TRACK). Set your transformer’s throttle position
to the desired top speed of the train. If the StationMaster does
not "light up", then reverse the direction on the transformer
to change the voltage polarity, or swap these two wires.
Attach 3 & 4 to your track. This is the
controlled output voltage.
Terminals 8 & 9 are the start DECEL sensor for the ends.
When this sensor detects a magnet the StationMaster will begin a decelerate,
pause, reverse, and then accelerate sequence. The sensor LED will light up when
this sensor is detected. The DECEL sensor should be placed 1 or 2 feet from the
ends, depending on the deceleration rate. One is required on each end.
*This sensor can be simulated by pressing programming button #1.
END Sensor - only when programmed to use sensors.
RR-Concepts.com
C
R
R
+
-
1
2
3
4
8
9
10
11
12
13
StationMaster
1
2
3
4
8
9
10
11
12
13
StationMaster