background image

AIR TEMpERATURE CONTROL

The RPB® 4000-01 Cool Air Tube cools 
compressed breathing air coming into 
the respirator by up to 30°F while the 
RPB® 4000-20 Hot Air Tube will heat the 
compressed air by up to 30°F. These 
maximize worker comfort and increase 
productivity in hot or cold climates.

AIR QUALITy MONITORING

The RPB® RADEX CO MONITOR™ helps 
ensure worker safety with a unique 
traceability feature that monitors and 
records carbon monoxide levels, and 
temperature. This data that provides 
certainty of monitor functioning and can 
be stored for up to two years allowing 
analysis of plant and field air quality.

1 866 494 4599

www.rpbsafety.com

OTHER pRODUCTS

Rpb® NOVA 3® RESpIRATOR

The RPB® NOVA 3® combines breakthrough 
protection technology with advanced 
comfort and functionality, surpassing even 
the most rigorous industry standards and 
the demands of the most quality-conscious 
companies. Designed to optimize safety 
and productivity, and to minimize worker 
downtime, the helmet has a host of 
features that maximize its lifetime value.

C E R T I F I E D   C O M P A N Y

Summary of Contents for radex

Page 1: ...INSTRUCTION MANUAL ADVANCED AIRLINE FILTER...

Page 2: ...Samoset Rd Royal Oak MI 48073 USA T 1 866 494 4599 F 1 866 494 4509 E sales us rpbsafety com www rpbsafety com Rpb Safety Asia pacific Headquarters 652 Halswell Junction Road Hornby South 8042 New Ze...

Page 3: ...located in a safe clean ambient air environment constructed and situated so as to prevent entry of contaminated air into the air supply system and as detailed in OSHA Regulation 29 CFR 1910 134 i Tot...

Page 4: ...not limited to the following Grade D air components O2 Oxygen CO2 Carbon Dioxide CO Carbon Monoxide H2O Water Moisture Content Hydrocarbons Oil Mist Total Particulates The maximum allowable level of t...

Page 5: ...air supply to the inlet must be shut off completely before performing any work on the Radex Airline Filter 1 The Radex Airline Filter should be assembled operated and maintained by trained and experi...

Page 6: ...ith the arrows on the filter You will hear a click when the base is in the final position Turn the filter in a clockwise direction and lock into position Note The base mount will only fit in two posit...

Page 7: ...ator assembly is tightened before mounting onto the Radex Airline Filter Use thread sealant on all fittings Fit the complete regulator assembly onto the top of the Radex Airline Filter lid Once the re...

Page 8: ...and check fitting for any air leaks tighten accordingly warning DO NOT over tighten fittings as over tightening could crack the Filter Casting To fit optional micro mist filter 04 925 first thread th...

Page 9: ...fold and tighten Thread all six 04 964 Couplers into the 04 065 Manifold and tighten The pressure relief valve must be connected to protect the Radex Airline Filter from over pressurizing Thread the c...

Page 10: ...ghten super high flow regulator assembly Note If the Pressure Gauge on the Super High Flow Regulator and the Pressure Gauge on the Manifold are reading more than 10psi apart your cartridge is blocked...

Page 11: ...onoxide and other toxic gases from the breathing air supply A Radex carbon monoxide monitor 08 200 must be used at all times Supplied air passing through this Radex Airline Filter must meet the requir...

Page 12: ...ten to 10ft lb torque 6 Record the data on the sticker supplied with the filter cartridge and place onto the Radex Airline Filter maintenence Filter cartridge replacement The filter cartridge should b...

Page 13: ...valve partially open to bleed the moisture When fitted with auto drain assembly 04 924 moisture will automatically drain from the unit as particles which could cause blockages LID BOLTS ORINGS The Rad...

Page 14: ...re Relief Valve 125 psi 04 916 7 3 8 Hex Nipple 04 917 8 Lid 04 918 9 Oring set of 2 04 919 10 Filter Cartridge APF 3100 11 Bolt Nut Washer set of 4 04 920 12 Body 04 921 13 Drain Tap 04 922 14 Base M...

Page 15: ...15 1 2 3 11 4 5 7 6 8 10 9 18 12 17 16 15 13 14 19...

Page 16: ...onoxide levels and temperature This data that provides certainty of monitor functioning and can be stored for up to two years allowing analysis of plant and field air quality 1866 494 4599 www rpbsafe...