OpERATION

AIR pRESSURE

The air pressure supplied to the Radex 
Airline Filter should not exceed 125psi (860 
kpa). When setting the outlet pressure 
using the pressure regulator refer to your 
respirator instruction manual to set the 
correct air pressure.

AIR TEMpERATURE

The Air supplied to the Radex Airline Filter 
should not exceed 140 degrees Fahrenheit 
(60 degrees Celsius). Do not connect 
the Radex Airline Filter directly to the 
compressor outlet manifold.

AIR QUALITy

The Radex Airline Filter does not remove 
carbon monoxide and other toxic gases 
from the breathing air supply. A Radex 
carbon monoxide monitor 08-200 must 
be used at all times. Supplied air passing 
through this Radex Airline Filter must meet 
the requirements of Grade D. EN 12021 
or AS/NZS 1715 refer to your relevant 
authorities for copies of these standards. 
Regular tests of the compressed air must 
be carried out to ensure it meets the 
requirements for breathable air.

AIR CONNECTIONS

Connect air fittings that meet the 
requirements of OSHA for respirable air. The 
inlet thread size is 1: NPT. All connections 
should be sealed using liquid thread 
sealant. If the Radex Airline Filter is hard 
piped an isolation valve must be used to 
enable depressurisation for servicing.

Summary of Contents for radex

Page 1: ...INSTRUCTION MANUAL ADVANCED AIRLINE FILTER...

Page 2: ...Samoset Rd Royal Oak MI 48073 USA T 1 866 494 4599 F 1 866 494 4509 E sales us rpbsafety com www rpbsafety com Rpb Safety Asia pacific Headquarters 652 Halswell Junction Road Hornby South 8042 New Ze...

Page 3: ...located in a safe clean ambient air environment constructed and situated so as to prevent entry of contaminated air into the air supply system and as detailed in OSHA Regulation 29 CFR 1910 134 i Tot...

Page 4: ...not limited to the following Grade D air components O2 Oxygen CO2 Carbon Dioxide CO Carbon Monoxide H2O Water Moisture Content Hydrocarbons Oil Mist Total Particulates The maximum allowable level of t...

Page 5: ...air supply to the inlet must be shut off completely before performing any work on the Radex Airline Filter 1 The Radex Airline Filter should be assembled operated and maintained by trained and experi...

Page 6: ...ith the arrows on the filter You will hear a click when the base is in the final position Turn the filter in a clockwise direction and lock into position Note The base mount will only fit in two posit...

Page 7: ...ator assembly is tightened before mounting onto the Radex Airline Filter Use thread sealant on all fittings Fit the complete regulator assembly onto the top of the Radex Airline Filter lid Once the re...

Page 8: ...and check fitting for any air leaks tighten accordingly warning DO NOT over tighten fittings as over tightening could crack the Filter Casting To fit optional micro mist filter 04 925 first thread th...

Page 9: ...fold and tighten Thread all six 04 964 Couplers into the 04 065 Manifold and tighten The pressure relief valve must be connected to protect the Radex Airline Filter from over pressurizing Thread the c...

Page 10: ...ghten super high flow regulator assembly Note If the Pressure Gauge on the Super High Flow Regulator and the Pressure Gauge on the Manifold are reading more than 10psi apart your cartridge is blocked...

Page 11: ...onoxide and other toxic gases from the breathing air supply A Radex carbon monoxide monitor 08 200 must be used at all times Supplied air passing through this Radex Airline Filter must meet the requir...

Page 12: ...ten to 10ft lb torque 6 Record the data on the sticker supplied with the filter cartridge and place onto the Radex Airline Filter maintenence Filter cartridge replacement The filter cartridge should b...

Page 13: ...valve partially open to bleed the moisture When fitted with auto drain assembly 04 924 moisture will automatically drain from the unit as particles which could cause blockages LID BOLTS ORINGS The Rad...

Page 14: ...re Relief Valve 125 psi 04 916 7 3 8 Hex Nipple 04 917 8 Lid 04 918 9 Oring set of 2 04 919 10 Filter Cartridge APF 3100 11 Bolt Nut Washer set of 4 04 920 12 Body 04 921 13 Drain Tap 04 922 14 Base M...

Page 15: ...15 1 2 3 11 4 5 7 6 8 10 9 18 12 17 16 15 13 14 19...

Page 16: ...onoxide levels and temperature This data that provides certainty of monitor functioning and can be stored for up to two years allowing analysis of plant and field air quality 1866 494 4599 www rpbsafe...

Reviews: