13
DRAINING MOISTURE
Water will accumulate in the filter tank,
this should be drained by opening the
ball valve. This should be done each day.
In very humid climates or if there is large
amounts of water in the air supply it is
recommended to leave the ball valve
partially open to bleed the moisture. When
fitted with auto drain assembly 04-924,
moisture will automatically drain from
the unit as particles which could cause
blockages.
LID bOLTS, ORINGS
The Radex Airline Filter lid bolts should
be checked to ensure that they are tight.
The lid bolts 04-920 should be replaced
when replacing the filter cartridge. The
recommended tightness for the lid bolts is
10 ft/lbs. Check the orings 04-919 and
replace if damaged.