7
Do not use two outputs to separate the connection, if separate a
continuous connection to branch, DMX512 splitter is necessary.
Attention! Do not overload the connection. One continuous
connection can only connect up to 32 devices.
If use the DMX512 splitter. At first connect DMX512
Splitter input terminal to controller .And then connected from
the splitter output terminal to next device.
Do as above guide to connect other device, and finally coupled with
terminal insertion.
5. ALTERNATING CURRENT POWER SUPPLY
5.1 VOLTAGE, POWER, FUSE SPECIFICATION
Input Voltage
Total Power
Frequency
110-240V
400W
50/60Hz
5.2 POWER PROTECT
The equipment must be operated by professionals; Make sure that the voltage of
power supply must be comply with the voltage identified on the lamp, and must
have an overload or leakage electrical protection.
ATTENTION!
Factory has equipped the standard 3 pin plug socket. Connect
the power supply as below table.
If lamp cable is damaged, replacement should be operate by
factory or qualified staff. Any question, please contact
professionals or talk to a qualified electrician.
Live wire(L)
Null(N)
Ground wire
RED
BLUE
Green
Fuse voltage
Fuse voltage
Specification
250V
6A
5×20