background image

10

  fReSCaPURe

   TyPiCal UndeR-CoUnTeR sysTem insTallaTion

   dRillinG a hole in a sTainless sTeel sink:

   Locate an area on your sink to install the  

Dedicated Drinking Water Faucet.

 (Make  

certain there are no support ribs under the sink  
in that area.) 

Cover the designated location  

for the faucet installation on sink with masking 
tape. Use the punch and hammer to make 
a light indentation at the designated faucet 
installation location.

   Using a 1/8” high speed drill bit, drill a pilot 

hole in the sink. 

   Use a 1” hole saw to enlarge the pilot hole  

to final size.

 

this type of sink can be scratched very easily. Use extreme care.  

If you have any doubts about doing this yourself, consult a licensed plumber 

cAuTION

2

3

1

Dedicated 

Drinking Water 

Faucet

Monitor

Filter 

Housing

RED 

Tubing

WHITE 

Tubing

T-Valve

BLUE 

Tubing

Cable

Hot

Cold

Summary of Contents for FP6000CT

Page 1: ...IMPORTANT Read and Save these Instructions Questions or Comments 1 800 279 3373 8am 5pm Central Standard Time Use Care Manual Water filtration systems MODELS FP6000CT FP6000UC...

Page 2: ...rtridge Countertop System 6 Installation Under Counter System Model FP6000UC 9 DRILLING A HOLE IN A STAINLESS STEEL SINK 10 DRILLING A HOLE IN A PORCELAIN CERAMIC SINK 11 Faucet Installation 12 System...

Page 3: ...hing RED indicating the rated capacity has been reached When the flow rate diminishes When you notice a taste or odor recurrence 3 Do not use with water that is microbiologically unsafe or of unknown...

Page 4: ...use sanitary gloves to remove the Filter Cartridge Place Cartridge into clean plastic bag seal and refrigerate Once you return re install the Cartridge per the Replacement Instructions and continue to...

Page 5: ...839 L Replacement Filter Cartridge WF0705 Monitor Electronic LED Rated Service Flow 60 psi 0 75 Gal min 2 84 L min Housing Construction 316 Surgical Stainless Steel Lid Construction High Impact ABS Ma...

Page 6: ...3 RP6154 Housing Clamp includes Knob T Bolt 4 RP6155 Stainless Steel Filter Housing 5 RP6160 Base 6 RP6161 Faucet Kit includes 7 Dedicated Water Faucet 8 Monitored Beauty Ring 9 Rubber Washer 10 C Wa...

Page 7: ...ucet Next thread the Diverter Valve to the Adapter 6 If your kitchen faucet does not have threads measure the inside diameter of your faucet and provide this information to your Independent Royal Pres...

Page 8: ...re System is ready for use REPLACING THE Filter Cartridge Countertop System The most important part of maintaining your FrescaPure Drinking Water System is replacing the Cartridge on a regular service...

Page 9: ...ockwise onto Lid until you feel resistance Make an additional quarter turn DO NOT over tighten 9 Make certain Gasket is firmly seated onto Lid With new Cartridge connected to Lid lower Cartridge into...

Page 10: ...e Monitor Cable inside the Enclosure Hinge Cover to front of Enclosure as shown then press rear portion of Cover into place Position the System next to your sink 16 Slowly turn the cold water ON and t...

Page 11: ...Drilling a Hole in a Stainless Steel Sink 3 8 Variable Speed Electric Drill 1 8 Drill Bit 1 Hole Saw Masking Tape Hammer Punch Installing the T Valve and Dedicated Drinking Water Faucet 5 8 and 3 4 Op...

Page 12: ...ith masking tape Use the punch and hammer to make a light indentation at the designated faucet installation location 2 Using a 1 8 high speed drill bit drill a pilot hole in the sink 3 Use a 1 hole sa...

Page 13: ...rill motor turning as slowly as possible after the initial cut has started in the porcelain the drill motor s R P M may be increased Avoid high R P M s during the initial penetration of the porcelain...

Page 14: ...Cable through Rubber Washer and slide firmly onto Faucet Stem 4 Insert the Red White and Blue Tube ends through Nut and thread Nut onto Faucet Stem Insert the C Washer between Nut and Rubber Washer an...

Page 15: ...e cold water supply line shut off the main water supply to your home 2 Locate an area under sink to place the Base The Base should be located directly under the area where the Dedicated Drinking Water...

Page 16: ...ort located on Monitor 10 Slowly turn cold water supply ON and turn the Lever on Dedicated Drinking Water Faucet downward Water will begin filling the System Upon initial startup the Monitored Beauty...

Page 17: ...t Lid upward This step will expose the Filter Cartridge 3 While holding Lid turn Cartridge counter clockwise to remove Wrap in newspaper and discard with normal refuse 4 Wash inside of Housing and Lid...

Page 18: ...N and turn the Lever on Dedicated Drinking Water Faucet downward Water will begin filling the System Upon initial startup the Monitored Beauty Ring will begin blinking GREEN YELLOW and RED five 5 time...

Page 19: ...FRESCAPURE 17 Notes...

Page 20: ...ive amounts of particles in the water supply may have caused premature plugging of the Filter Cartridge SOLUTION The Cartridge and Battery Shuttle must be replaced due to poor water conditions in your...

Page 21: ...UTION Press tube fitting firmly into Collar REASON 2 Tube end has been damaged elongated or not cut squarely SOLUTION Depress Collar using the Tool provided and pull Tube at the same time to remove Ob...

Page 22: ...ARE LIMITED IN DURATION TO THE SAME DURATION AS THE WRITTEN WARRANTY DESCRIBED ABOVE FOR YOUR COVERED PRODUCT Some states do not allow limitations on how long an implied warranty lasts accordingly th...

Reviews: