ROXELL - 009 - 2111
HAIKOO -- INSTRUCTIONS FOR THE USER
I--9
TROUBLE SHOOTING GUIDE
Switch off the current first. Use protection
DANGER
ACTIONS IN GREY BACKGROUND MUST BE DONE BY A TECHNICALLY TRAINED PERSON.
PROBLEM
CAUSE
CORRECTIVE ACTION
1.None of the feeder
lines run.
No current.
Replace defective fuses or reset circuit breakers.
Check current supply to the house.
Defective clock.
Replace defective clock.
Time clock not properly set.
Readjust tabs.
2.One/more lines do
not run.
Pans are empty
Wires from motor damaged.
Measure current in motor wires. Replace wires if
defective.
Thermal protection of motor switched
off.
See points 3. & 4. Reset motor overload button.
Defective sensor in the control unit, or
sensor not properly adjusted.
Check the good operation of the sensor.
Replace if necessary.
Control unit not functioning properly.
Put the feed level ring in a higher position. Hang an extra
lamp above it. Check temperature. Control unit must be
the most attractive one, especially the control unit of
the feeder line below the Flex--Auger control unit.
The control unit does not functionproper-
ly when the feed windows are open
Check the motor suspension. Hang the motor horizon-
tally. Make sure that the main cable is stretched.
Defective
sensor/minimum
switch
control unit or 100kg hopper.
Check control unit sensor or switch. Replace if
necessary.
3.Motor is often
overloaded.
Oil on auger overloads the motor.
Clean the auger by running repeatedly 25kgs of feed
through the line.
Not enough current supply to the motors. Check current supply at motor location. Start the motor.
Measure start current on motors. Wiring must be thick
enough to guarantee good operation of the system.
Object blocks the auger. Motor runs,
then stalls. Feed sticks to the tubes.
Check if there are no objects in the boot, the control unit
and the drop holes of the feeder pans. Remove any
objects.
4.Auger stalls.
Anchor bearing worn out or broken.
Replace bearing.
Gently
slide auger back into the tubes.
Don’t let it jump back : your
finger
or the
bearing
could
be
damaged
.
Auger not enough stretched.
Shorten the auger.
Object blocks the auger.
Remove the object.
5.Tubes / boot wear rap-
idly, much noise
when system runs.
Auger kinked or bent at the wear point.
Auger end overlaps the anchor end.
Make sure not to kink the auger when using gripping pli-
ers. Auger must not overlap the anchor end.
6.Not enough feed
supplied to fill up
the lines.
Flex--Auger drop holes are too small or
point upwards.
Make holes wider/turn tubes with holes downwards.
Flow regulator in boot of feed supply
system blocks passage of the feed.
Adjust flow regulator to get a higher capacity.
Flex--Auger capacity is too low.
Checkthecapacityof theFlex--Augeraccordingthespe-
cifications.
Check the installation of the Flex--Auger.
Not enough time set on the time clock.
Extend operation time per meal.
7.Feed drops directly
on the adjuster ring
of the grill.
Pan not installed over the hole.
Remove the top support. Install the pan ass’y over
the hole and the lips.
Summary of Contents for HaiKoo
Page 6: ...HAIKOO INSTRUCTIONS FOR THE USER ROXELL 009 3507 NOTES ...
Page 7: ...I 1 PART I INSTRUCTIONS FOR THE USER ...
Page 8: ...HAIKOO INSTRUCTIONS FOR THE USER ROXELL 009 2111 I 2 ...
Page 50: ......
Page 51: ...PART III INSTALLATION INSTRUCTIONS ...
Page 52: ...HAIKOO INSTALLAITON INSTRUCTIONS ROXELL 009 1105 NOTES ...