Troubleshooting ICS Direct
Fundamental signal
combinations
The control unit has two diodes and a buzzer, which indicate how the control system is working.
The components light and sound at different intervals and combinations.
The components are controlled by the signals that pass between the control unit and the other parts of the
control system.
Correct function
- When the green LED
lights with a fixed light the control system
works correctly.
System inactive
- When the green and
red LEDs light with a fixed light the drive
mode switch is not activated.
Calibration
- When the green and red
LEDs flash quickly and the buzzer sounds
the rollers are not calibrated correctly.
Input signal
- When the green and red
LEDs flash slowly and the buzzer sounds
the input signal does not work correctly.
Output signal
- When the green LED
flashes and the Red LED lights with a
fixed light and the buzzer sounds the
output signal does not work correctly.
Detailed troubleshooting
Calibration
Red LED
Green LED
Buzzer
Possible cause
Action
Flashes
quickly.
1 flash
Sounds
at the
same
rate as
the red
LED.
Roller left not calibrated. The
control system clears the roller’s
calibration and stops output
signals.
Cable breakage, connector play
or roller fault.
•
Calibrate the roller by pulling it to each
end position for at least 3 seconds.
•
Change the roller and perform the
calibration as set out above.
•
Contact the service workshop.
Flashes
quickly.
2 flashes
Sounds
at the
same
rate as
the red
LED.
Roller right not calibrated. The
control system clears the roller’s
calibration and stops output
signals.
Cable breakage, connector play
or roller fault.
Red LED
Green LED
Buzzer
Possible cause
Action
Extin-
guished
Fixed light Silent
System works.
None
Correct function
Red LED
Green LED
Buzzer
Possible cause
Action
Fixed light Fixed light Silent
System inactive.
Activate the system
System inactive.