© Rototilt Group AB
2018-03-26
trouble:3
English
EN
EN -
Output signal
Red LED
Green LED
Buzzer
Possible cause
Action
Fixed light
1 flash
Sounds
at the
same
rate as
the green
LED.
Functional fault on output
signal wire 1.
Output signal blocked.
•
Check the harness in terms of crush
damage or open circuit.
•
Check the condition of the valve.
•
Return the roller to the zero position.
•
Contact the service workshop.
To reset the fault indication, restart the
system by disconnecting the voltage on the
base machine.
Fixed light
2 flashes
Sounds
at the
same
rate as
the green
LED.
Functional fault on output
signal wire 2.
Output signal blocked.
•
Check the harness in terms of crush
damage or open circuit.
•
Check the condition of the valve.
•
Return the roller to the zero position.
•
Contact the service workshop.
To reset the fault indication, restart the
system by disconnecting the voltage on the
base machine.
Fixed light
3 flashes
Sounds
at the
same
rate as
the green
LED.
Functional fault on output
signal wire 3.
Output signal blocked.
•
Check the harness in terms of crush
damage or open circuit.
•
Check the condition of the valve.
•
Return the roller to the zero position.
•
Contact the service workshop.
To reset the fault indication, restart the
system by disconnecting the voltage on the
base machine.
Fixed light
4 flashes
Sounds
at the
same
rate as
the green
LED.
Functional fault on output
signal wire 4.
Output signal blocked.
•
Check the harness in terms of crush
damage or open circuit.
•
Check the condition of the valve.
•
Return the roller to the zero position.
•
Contact the service workshop.
To reset the fault indication, restart the
system by disconnecting the voltage on the
base machine.
Fixed light
5 flashes
Sounds
at the
same
rate as
the green
LED.
Start-up check that indicates
whether one of the valves is
not connected to the control
system.
•
Check the harness in terms of crush
damage or open circuit.
•
Check the condition of the valves.
•
Restart the control system.
•
Contact the service workshop.
To reset the fault indication, restart the
system by disconnecting the voltage on the
base machine.
Fixed light
6 flashes
Sounds
at the
same
rate as
the green
LED.
Functional fault on output signal
wire Auxiliary.
Output signal blocked.
•
Check the harness in terms of crush
damage or open circuit.
•
Check the condition of the valves.
•
Restart the control system.
•
Contact the service workshop.
To reset the fault indication, restart the
system by disconnecting the voltage on the
base machine.