15
The SV Mini spa controls have been designed with simplicity in mind. Their intelligent software constantly monitors the
spa water, automatically controlling the heater and filtration pump to ensure the desired set water temperature is
maintained and required level of daily filtration achieved.
With set-and-forget technology, the spa user simply selects their desired water temperature
(10
o
C - 41
o
C. Default = 38
o
C) and thereafter the spa control will automatically heat to and maintain that selected water
temperature. This is called demand heating - the filtration pump and heater will be activated when required to maintain
the set water temperature. The time spent heating the pool and running the filtration pump under normal operation will
be taken into account and where required the pump will run for additional periods every three hours to maintain the
minimum level of daily filtration as set by the user.
Dependant on the amount of normal spa use, set water temperature, minimum hours of filtration per day, climatic
conditions and season being experienced, the spa control will engage the heater and / or filtration pump for differing
periods of time, at differing times of day. The advanced software constantly monitors and recalculates after each heating
/ filtration cycle to ensure the correct daily filtration time is achieved and desired set water temperature is maintained.
Unless adjusted the SV controller will automatically heat to and maintain the default temperature of 38
o
C. The water
temperature set point can be adjusted from 10
o
C to 41
o
C in steps of 0.2
o
C increments.
NOTES:
1.
During a heating cycle the SV Mini may raise the water temperature up to 0.
5
o
C above set temperature point to provide
an average water temperature of set point at most times.
2.
If an optional heat pump is
NOT fitted
the spa controller has
NO
ability to cool the spa water. Lowering the set
temperature point will NOT cause the water to cool.
3.
If an optional heat pump
IS fitted
the spa water
CAN
be cooled as well as heated. Lowering the set temperature point
will ensure the heat pump engages/disengages a cooling cycle (if required) to maintain the desired set water temperature
so long as H.PMP mode is set to AUTO.
4.
If the spa control has been in standby mode (idle) for some time and the set temperature point is adjusted, the
filtration/circulation pump may run for up to ten (10) minutes to complete a mixing cycle before
the heater / heat pump
engages to heat or cool (heat pump only) the water. To skip this mixing cycle and begin heating / (cooling) immediately
press the PUMP A button multiple times to toggle the filtration pump through ON/OFF/AUTO. Once AUTO is re-engaged
the heater will activate immediately.
PUMP OPERATION
Adjusting Set Temperature
-
Press and hold the UP or DOWN button to begin
set temperature adjustment
-
The display will show the (S.TMP) set
temperature indicator icon, the main digits flash
and
temperature
will
begin
adjusting
-
Press the UP or DOWN buttons to adjust the set
temperature by 0.2
o
C increments to your desired
temperature
-
Press OK to confirm and save setting, or wait for
the 10 second idle timeout. The main digits will
stop flashing and display returns to default
display mode