Function of the device
The detector produces a stable electromagnetic field with the help of a sensor coil. This
magnetic field induces eddy currents in the object being tested.
As different materials absorb electromagnetic microwaves in different ways, the device
makes it possible not only to detect the object but to determine its exact location and
range.
Fitting and changing the batteries
The device is battery powered and a 9V battery block (6F22/6LR61) must be used.
The battery must be fitted before the device is used for the first time. The battery must be
changed when the device can no longer be switched on or when the battery status light is
flashing. Proceed as follows:
Switching ON/OFF
Press the ON/OFF button to switch the detector on. Press the ON/OFF button again to
switch the detector off. The device will automatically switch off if inactive for 5 minutes.
Note: When switched on the detector automatically selects the metal detection mode
- Open the battery compartment cover.
- Remove the old battery.
- Insert a new 9V battery block-
batteries (6F22/6LR61) into the battery
compartment. Consult the polarity
markings in the battery compartment.
- Close the battery compartment cover.
Further instructions on the use of and care for batteries can be found in the section on
maintenance and cleaning.
Before using the device
Using the device