background image

17

User manual

Split wall air conditioner - VERSU W

during heating (only for cooling and heating units) to the set value.

7.  Water condensation

Water may condense on the surface of the indoor unit operating in conditions of high relative humidity 
(over 80%). In this case, set the maximum opening angle of the horizontal louvers and run the fan at high 
speed.

8.  Heating mode

An air conditioner in heating mode draws heat from the environment via the outdoor unit and releases it 
using the indoor unit. A drop in the outside air temperature will reduce the amount of heat transported. 
At the same time, the heat load on the air conditioner increases due to the increased temperature 
difference between the indoor and outdoor units. If the air conditioner is unable to provide a comfortable 
temperature, we recommend using an additional heating device.

9.  Automatic resume function

•  Power failure will interrupt the air conditioner operation. The operation indicator of indoor units not 

equipped with the resume function will flash after recovery of power. Pressing the ON/OFF button on 
the wireless controller will then enable the device to be turned on again.

•  In the case of units equipped with the auto-wake-up function, the device that has been recharged will 

restart automatically and start working with the previous settings.

Problem

Flashing operation indicator.

The unit may shut down or continue to run 
in safe mode (depending on the model).
If the problem persists after 10 minutes, 
disconnect the power and reconnect it. If the 
error persists, disconnect the device from 
the power supply and consult your nearest 
service center.

One of the following codes
error appears on the display:
E0, E1, E2, E3 ...., P0, P1, P2,
P3 ...., or F0, F1, F2, F3. ...
.......................................

Frequently blown fuses or frequent 
operation of the circuit breaker.

Turn off the air conditioner, unplug it, then 
contact your nearest dealer.

Water or other object has fallen on the 
air conditioner.

A noticeable unpleasant smell or 
audible disturbing sounds.

PART 4. TROUBLESHOOTING

Summary of Contents for VG26W

Page 1: ...1 User manual Split wall air conditioner VERSU W EN User manual VERSU W VM26W VM35W VG26W VG35W VS26W VS35W...

Page 2: ...peration of the device 11 Adjusting the air flow direction 12 The way the air conditioner works 13 PART 3 SERVICE OPERATIONS 14 Activities before starting the service 14 Cleaning the device and filter...

Page 3: ...ollection you can pass the device without the cost B When you buy a new device the seller will accept the old device without any fees C Manufacturer will take the product from buyer produkt without ch...

Page 4: ...ore installation using maintenance Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer Do not pierce or bum the appliance The appliance s...

Page 5: ...liance gives off smoke or there is a smell of burning immediately cut off the power supply and contact the Service Centre The appliance must be fitted with means for disconnection from the supply main...

Page 6: ...and must not be used for any other purpose such as for drying clothes cooling food etc Rave repairs carried out only by an authoris ed Service Centre of the manufacturer Inco rrect repair could expos...

Page 7: ...e outdoor unit The obstruction of these openings causes a re duction in the operative efficiency of the con ditioner with possible consequent failures or damages Do not install the appliance in enviro...

Page 8: ...Work indicator During operation the diode informs about the operation of the device 10 Signal receiver 1 2 3 4 5 7 6 8 9 fresh defrost run timer PART 1 AIR CONDITIONER CONSTRUCTION 1 AIR CONDITIONER...

Page 9: ...evice works during self cleaning Fan mode FAN fan speed low LOW heating mode HEAT fan speed low cooling heating units only fan mode stop off OFF REMEMBER The self cleaning function can only be activat...

Page 10: ...on to control the device during a remote control failure You can get to it by opening the front panel The button should only be used if a wireless remote control fails or needs service AUTO COOL Contr...

Page 11: ...is carried out by means of a lever IMPORTANT Do not put your fingers in the place from which it flows out or into which air is sucked A fan that rotates at high speed can be hazardous ATTENTION When t...

Page 12: ...the temperature constant for another 5 hours and then turn off the unit This treatment allows you to save energy while maintaining comfortable conditions during the night Drying mode During dehumidifi...

Page 13: ...the power supply before cleaning the device ATTENTION Heavily soiled device can be wiped with a damp cold cloth Wipe the damp surfaces dry Do not use chemicals or dust cloths Do not use gasoline thin...

Page 14: ...y lift it up Take the filter out of the holder and pull it downwards 3 Pull out the filter from the indoor unit Clean the filter every 2 weeks using a vacuum cleaner or water Dry the damp filter in a...

Page 15: ...Check that the cables are not damaged and that they are properly connected Clean the indoor unit and filters Check that the filters have been mounted After a long period of non use of the device chec...

Page 16: ...fog escaping from the indoor unit Due to the large temperature difference between the air inlet and outlet and the high relative humidity fog may come out of the indoor unit in cooling mode Fog may a...

Page 17: ...the air conditioner operation The operation indicator of indoor units not equipped with the resume function will flash after recovery of power Pressing the ON OFF button on the wireless controller wi...

Page 18: ...only cooling and heating air in the room efficiently Air stream brings out out of the device Incorrect temperature settings Set the appropriate temperature value For details see Using the Wireless Re...

Page 19: ...rania szybko ci wentylatora 4 SLEEP W cz Wy cz funkcj SLEEP Pozwala utrzyma najbardziej komfortow temperatur oraz oszcz dno energii Funkcja ta jest dost pna tylko w trybie COOL HEAT oraz AUTO Informac...

Page 20: ...0 0H 11 TIMER OFF Naci ni cie tego przycisku ustawi czas automatycznego wy czenia Ka de naci ni cie zwi kszy czas automatycznego wy czenia o 30 minut Podczas gdy ustawienia czasu wy wietlaj 10H ka de...

Page 21: ...czony Wy wietlacz baterii Wykryto s abe baterie Niedost pna w tej jednostce Wy wietlana gdy TIMER ON jest ustawiony Wy wietlana gdy TIMER OFF jest ustawiony Pokazuje ustawion temperatur lub temperatu...

Page 22: ...OCK clock setting button 6 SPEED fan speed button 7 TIMER button 8 SWING function button 9 TIMER setting cancel button 10 Operating mode indicators 11 Temperature display 12 Clock display 13 TIMER ON...

Page 23: ...setting button Hold CLOCK for more than 4 seconds and the clock on the display will flash at a frequency of 0 5 seconds Using the UP buttons and DOWN Set the desired time Pressing the buttons once wi...

Page 24: ...LER SUPPORT 4 CONNECTION DIAGRAM E B A D C E B A D C RUN GDN 5V Wired controller Communication channel Indoor unit control panel Indoor unit Connecting cable with display panel Display panel A 5 core...

Page 25: ...re are no terminals then the 5 wire cable should be connected directly to the controller 5 INSTALLATION Electrical box of the indoor unit Indoor electrical control box terminal Back side of the wired...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...28 User manual Split wall air conditioner VERSU W www rotenso com email info rotenso com Installer stamp...

Reviews: