background image

4

User manual

Split wall air conditioner - VERSU W

SAFETY PRECAUTIONS

1. INTRODUCTION TO REFRIGERANTS R32

The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. The two kinds of 
refrigerants are combustible and odorless. Moreover, they can bum and explode under certain condition. How-
ever, there will be no risk of buming and explosion if you comply with the following table to install your air 
conditioner in a room with an appropriate area and use it correctly. 

Compared with ordinary refrigerants, Refrigerants R32 is environmentally friendly and do not destroy the 
ozone sphere and that their values of greenhouse effect are also very low. 

2. ROOM AREA REGUESTS FOR AIR CONDITIONER WITH REFRIGERANTS R32

Refrigerants

Capac i ty (Btu) 

Room Area 

R32

9K

Above 4 m

2

 

12K

Above 4 m

2

 

18K

Above 15 m

2

 

22K/24K 

Above 25 m

2

 

 

 

WARNINGS

•  Please read the manual before installation, using, maintenance. 
•  Do not use means to accelerate the defrosting process or to clean, other than those recommended by 

the manufacturer.

•  Do not pierce or bum the appliance.
•  The appliance shall be stored in a room without continuously operating sources (for example: open 

flames, an operating ignition gas appliance or an operating electric heater.)

•  Please contact the nearest after-sale service center when maintenance is necessary. At the time of 

maintenance, the maintenance personnel must strictly comply with the Operation Manual provided by 
the corresponding manufacturer and any non-professional is prohibited to maintain the air conditioner.

•  It is necessary to comply with the provisions of gas-related national laws and regulations.
•  It is necessary to clear away the refrigerant in the system when maintaining or scrapping an air 

conditioner.

WARNING

 

Risk of fire/flammable materials

(Required for R32/R290 units only)

IMPORTANT NOTE 

Read the user manual, installation manual and 

service manual carefully before installing or 

operating your new air conditioning unit. 

Summary of Contents for VG26W

Page 1: ...1 User manual Split wall air conditioner VERSU W EN User manual VERSU W VM26W VM35W VG26W VG35W VS26W VS35W...

Page 2: ...peration of the device 11 Adjusting the air flow direction 12 The way the air conditioner works 13 PART 3 SERVICE OPERATIONS 14 Activities before starting the service 14 Cleaning the device and filter...

Page 3: ...ollection you can pass the device without the cost B When you buy a new device the seller will accept the old device without any fees C Manufacturer will take the product from buyer produkt without ch...

Page 4: ...ore installation using maintenance Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer Do not pierce or bum the appliance The appliance s...

Page 5: ...liance gives off smoke or there is a smell of burning immediately cut off the power supply and contact the Service Centre The appliance must be fitted with means for disconnection from the supply main...

Page 6: ...and must not be used for any other purpose such as for drying clothes cooling food etc Rave repairs carried out only by an authoris ed Service Centre of the manufacturer Inco rrect repair could expos...

Page 7: ...e outdoor unit The obstruction of these openings causes a re duction in the operative efficiency of the con ditioner with possible consequent failures or damages Do not install the appliance in enviro...

Page 8: ...Work indicator During operation the diode informs about the operation of the device 10 Signal receiver 1 2 3 4 5 7 6 8 9 fresh defrost run timer PART 1 AIR CONDITIONER CONSTRUCTION 1 AIR CONDITIONER...

Page 9: ...evice works during self cleaning Fan mode FAN fan speed low LOW heating mode HEAT fan speed low cooling heating units only fan mode stop off OFF REMEMBER The self cleaning function can only be activat...

Page 10: ...on to control the device during a remote control failure You can get to it by opening the front panel The button should only be used if a wireless remote control fails or needs service AUTO COOL Contr...

Page 11: ...is carried out by means of a lever IMPORTANT Do not put your fingers in the place from which it flows out or into which air is sucked A fan that rotates at high speed can be hazardous ATTENTION When t...

Page 12: ...the temperature constant for another 5 hours and then turn off the unit This treatment allows you to save energy while maintaining comfortable conditions during the night Drying mode During dehumidifi...

Page 13: ...the power supply before cleaning the device ATTENTION Heavily soiled device can be wiped with a damp cold cloth Wipe the damp surfaces dry Do not use chemicals or dust cloths Do not use gasoline thin...

Page 14: ...y lift it up Take the filter out of the holder and pull it downwards 3 Pull out the filter from the indoor unit Clean the filter every 2 weeks using a vacuum cleaner or water Dry the damp filter in a...

Page 15: ...Check that the cables are not damaged and that they are properly connected Clean the indoor unit and filters Check that the filters have been mounted After a long period of non use of the device chec...

Page 16: ...fog escaping from the indoor unit Due to the large temperature difference between the air inlet and outlet and the high relative humidity fog may come out of the indoor unit in cooling mode Fog may a...

Page 17: ...the air conditioner operation The operation indicator of indoor units not equipped with the resume function will flash after recovery of power Pressing the ON OFF button on the wireless controller wi...

Page 18: ...only cooling and heating air in the room efficiently Air stream brings out out of the device Incorrect temperature settings Set the appropriate temperature value For details see Using the Wireless Re...

Page 19: ...rania szybko ci wentylatora 4 SLEEP W cz Wy cz funkcj SLEEP Pozwala utrzyma najbardziej komfortow temperatur oraz oszcz dno energii Funkcja ta jest dost pna tylko w trybie COOL HEAT oraz AUTO Informac...

Page 20: ...0 0H 11 TIMER OFF Naci ni cie tego przycisku ustawi czas automatycznego wy czenia Ka de naci ni cie zwi kszy czas automatycznego wy czenia o 30 minut Podczas gdy ustawienia czasu wy wietlaj 10H ka de...

Page 21: ...czony Wy wietlacz baterii Wykryto s abe baterie Niedost pna w tej jednostce Wy wietlana gdy TIMER ON jest ustawiony Wy wietlana gdy TIMER OFF jest ustawiony Pokazuje ustawion temperatur lub temperatu...

Page 22: ...OCK clock setting button 6 SPEED fan speed button 7 TIMER button 8 SWING function button 9 TIMER setting cancel button 10 Operating mode indicators 11 Temperature display 12 Clock display 13 TIMER ON...

Page 23: ...setting button Hold CLOCK for more than 4 seconds and the clock on the display will flash at a frequency of 0 5 seconds Using the UP buttons and DOWN Set the desired time Pressing the buttons once wi...

Page 24: ...LER SUPPORT 4 CONNECTION DIAGRAM E B A D C E B A D C RUN GDN 5V Wired controller Communication channel Indoor unit control panel Indoor unit Connecting cable with display panel Display panel A 5 core...

Page 25: ...re are no terminals then the 5 wire cable should be connected directly to the controller 5 INSTALLATION Electrical box of the indoor unit Indoor electrical control box terminal Back side of the wired...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...28 User manual Split wall air conditioner VERSU W www rotenso com email info rotenso com Installer stamp...

Reviews: