background image

9

User manual

Split wall air conditioner - VERSU W

PART 2. OPERATING THE DEVICE

1. FUNKCJE SPECJALNE

Refrigerant leak detection function

With this new function, the detection of refrigerant leakage by the outdoor unit will be alerted by the 
appearance of the „EC” symbol on the display screen and the LEDs flashing.

Louver position memory function (optional)

This function allows you to remember the opening angle of the blind within the safe range. If the louver 
position is outside this range, the device will remember the safety angle limit value.
When the manual control button is pressed or the power cord plug is pulled out and reinserted into the mains 
socket, the blinds will revert to the standard setting.

We recommend not to set a low opening angle of the louvers as this may cause condensation and water 
dripping from the surface of the air conditioner.

Self cleaning function (optional)

•  When the heating unit is turned off, the unit will automatically clean the evaporator and keep it clean until 

the next operation.

•  Diagram of how the device works during self-cleaning: Fan mode (FAN), fan speed - low (LOW) - heating 

mode (HEAT), fan speed - low (cooling & heating units only) - fan mode - stop - off (OFF). 

REMEMBER:

•   The self-cleaning function can only be activated when the appliance is in cooling (AUTO COOL or FORCED 

COOL) and DRY mode.

•  It is recommended to run the unit in cooling mode for at least half an hour before activating the function. 

Running the self-cleaning function will cancel the timer settings.

•  If you press the SELF CLEAN button while cleaning the appliance, the unit will turn off.

Mold prevention function (optional)

•  After turning off the unit working in COOL, DRY or AUTO (COOL) mode, the air conditioner will continue 

working for 7-10 minutes (depending on the model) at low fan speed. The unit working in HEAT mode 
after turning off will work for 30 seconds with low fan speed. Such behavior of the device will allow its 
interior to dry out of the condensate formed and prevent the growth of mold.

•  Do not restart the unit while the anti-mold function is active and the air conditioner is not turned off 

completely.

2. OPERATING RANGE

Cooling mode

Heating mode

Drying mode

Temperature in room

17°C~32°C

0°C~30°C

10°C~32°C

Temperature outside

-15°C~50°C 

-20°C~30°C

0°C~50°C

Mode

Temperature

Summary of Contents for VG26W

Page 1: ...1 User manual Split wall air conditioner VERSU W EN User manual VERSU W VM26W VM35W VG26W VG35W VS26W VS35W...

Page 2: ...peration of the device 11 Adjusting the air flow direction 12 The way the air conditioner works 13 PART 3 SERVICE OPERATIONS 14 Activities before starting the service 14 Cleaning the device and filter...

Page 3: ...ollection you can pass the device without the cost B When you buy a new device the seller will accept the old device without any fees C Manufacturer will take the product from buyer produkt without ch...

Page 4: ...ore installation using maintenance Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer Do not pierce or bum the appliance The appliance s...

Page 5: ...liance gives off smoke or there is a smell of burning immediately cut off the power supply and contact the Service Centre The appliance must be fitted with means for disconnection from the supply main...

Page 6: ...and must not be used for any other purpose such as for drying clothes cooling food etc Rave repairs carried out only by an authoris ed Service Centre of the manufacturer Inco rrect repair could expos...

Page 7: ...e outdoor unit The obstruction of these openings causes a re duction in the operative efficiency of the con ditioner with possible consequent failures or damages Do not install the appliance in enviro...

Page 8: ...Work indicator During operation the diode informs about the operation of the device 10 Signal receiver 1 2 3 4 5 7 6 8 9 fresh defrost run timer PART 1 AIR CONDITIONER CONSTRUCTION 1 AIR CONDITIONER...

Page 9: ...evice works during self cleaning Fan mode FAN fan speed low LOW heating mode HEAT fan speed low cooling heating units only fan mode stop off OFF REMEMBER The self cleaning function can only be activat...

Page 10: ...on to control the device during a remote control failure You can get to it by opening the front panel The button should only be used if a wireless remote control fails or needs service AUTO COOL Contr...

Page 11: ...is carried out by means of a lever IMPORTANT Do not put your fingers in the place from which it flows out or into which air is sucked A fan that rotates at high speed can be hazardous ATTENTION When t...

Page 12: ...the temperature constant for another 5 hours and then turn off the unit This treatment allows you to save energy while maintaining comfortable conditions during the night Drying mode During dehumidifi...

Page 13: ...the power supply before cleaning the device ATTENTION Heavily soiled device can be wiped with a damp cold cloth Wipe the damp surfaces dry Do not use chemicals or dust cloths Do not use gasoline thin...

Page 14: ...y lift it up Take the filter out of the holder and pull it downwards 3 Pull out the filter from the indoor unit Clean the filter every 2 weeks using a vacuum cleaner or water Dry the damp filter in a...

Page 15: ...Check that the cables are not damaged and that they are properly connected Clean the indoor unit and filters Check that the filters have been mounted After a long period of non use of the device chec...

Page 16: ...fog escaping from the indoor unit Due to the large temperature difference between the air inlet and outlet and the high relative humidity fog may come out of the indoor unit in cooling mode Fog may a...

Page 17: ...the air conditioner operation The operation indicator of indoor units not equipped with the resume function will flash after recovery of power Pressing the ON OFF button on the wireless controller wi...

Page 18: ...only cooling and heating air in the room efficiently Air stream brings out out of the device Incorrect temperature settings Set the appropriate temperature value For details see Using the Wireless Re...

Page 19: ...rania szybko ci wentylatora 4 SLEEP W cz Wy cz funkcj SLEEP Pozwala utrzyma najbardziej komfortow temperatur oraz oszcz dno energii Funkcja ta jest dost pna tylko w trybie COOL HEAT oraz AUTO Informac...

Page 20: ...0 0H 11 TIMER OFF Naci ni cie tego przycisku ustawi czas automatycznego wy czenia Ka de naci ni cie zwi kszy czas automatycznego wy czenia o 30 minut Podczas gdy ustawienia czasu wy wietlaj 10H ka de...

Page 21: ...czony Wy wietlacz baterii Wykryto s abe baterie Niedost pna w tej jednostce Wy wietlana gdy TIMER ON jest ustawiony Wy wietlana gdy TIMER OFF jest ustawiony Pokazuje ustawion temperatur lub temperatu...

Page 22: ...OCK clock setting button 6 SPEED fan speed button 7 TIMER button 8 SWING function button 9 TIMER setting cancel button 10 Operating mode indicators 11 Temperature display 12 Clock display 13 TIMER ON...

Page 23: ...setting button Hold CLOCK for more than 4 seconds and the clock on the display will flash at a frequency of 0 5 seconds Using the UP buttons and DOWN Set the desired time Pressing the buttons once wi...

Page 24: ...LER SUPPORT 4 CONNECTION DIAGRAM E B A D C E B A D C RUN GDN 5V Wired controller Communication channel Indoor unit control panel Indoor unit Connecting cable with display panel Display panel A 5 core...

Page 25: ...re are no terminals then the 5 wire cable should be connected directly to the controller 5 INSTALLATION Electrical box of the indoor unit Indoor electrical control box terminal Back side of the wired...

Page 26: ...NOTES...

Page 27: ...NOTES...

Page 28: ...28 User manual Split wall air conditioner VERSU W www rotenso com email info rotenso com Installer stamp...

Reviews: