GIRU W - Portable air conditioner
17
User manual
PART 4. OPERATIONS AND FUNCTIONS
6.
UP (+) and DOWN (-) buttons
Used to adjust (increasing/decreasing) temperature settings in 1°C/1°F(or2°F) increments in a range of
17°C/62°F to 30°C/86°F(or 88°F) or the TIMER setting in a range of 0~24hrs or The humidity settings in
a range of 35%RH(Relative Humidity) to 85%RH (Relative Humidity) in 5% increments(only for models
with humidity sensor).
NOTE
: The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To
convert from one to the other, press and hold the Up and Down buttons at the same time for 3 seconds.
4.
POWER button
Power switch on/off.
8.
LED display
Shows the set temperature in °C or °F and the Auto-timer settings and the humidity settings (only for
modles with humidity sensor). While on DRY and FAN modes, it shows the room temperature.
Shows Error codes and protection code:
E1-Room temperature sensor error.
E2-Evaporator temperature sensor error.
E4-Display panel communication error.
EC-Refrigerant leakage detection malfunction (on some models).
P1-Bottom tray is full--Connect the drain hose and drain the collected water away. If protection
repeats, call for service.
NOTE:
When one of the above malfunctions occurs, turn off the unit, and check for any obstructions.
Restart the unit, if the malfunction is still present, turn off the unit and unplug he power cord. Contact
the manufacturer or its service agents or a similar qualified person for service.
2. OPERATIONS
1. Exhaust hose installation
The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. For COOL or
AUTO mode must be installed exhaust hose. For FAN, DEHUMIDIIFY(without humidity sensor) mode must be
removed exhaust hose.
2. COOL operation
• Press the "MODE" button until the "COOL" indicator light comes on.
• Press the ADJUST buttons "+" or "-" to select your desired room temperature. The temperature can be set within
a range of 17°C~30°C/62°F~88°F (or 86°F).
• Press the "FAN SPEED" button to choose the fan speed.
3. DRY operation
• Press the "MODE" button until the "DRY" indicator light comes on.
• Under this mode, you cannot select a fan speed or adjust the temperature. The fan motor operates at LOW
speed.
• Keep windows and doors closed for the best dehumidifying effect.
• Do not put the duct to window when you can’t set the humidity level (portable without humidity sensor). -You
can set the humidity level when the unit has humidity sensor. Please put the back duct for best dehumidification
effect, but the duct doesn’t need to connect to window.