background image

Review date

Service note

Service stamp

Signature

1

2

3

4

REGISTER

 FOR

 AIR

 C

ONDITIONERS

 PERIODIC

 RE

VIE

W

S

Date of repair

Service note

Service stamp

Signature

1

2

3

4

REGISTER OF REP

AIRS

Summary of Contents for Giru G26W

Page 1: ...ENG GIRU W Giru G26W Giru G35W User manual...

Page 2: ...anel 15 PART 4 OPERATIONS AND FUNCTIONS 16 Button functions 16 Operations 17 Other features 18 Water drainage 19 PART 5 MAINTENANCE 21 Clean the filter 21 Clean the unit 21 Store the unit when not in...

Page 3: ...costs D Products of this type contains valuable elements it can be sold sprzedane on purchase of metals Throwing the device on wild exposes you to the risk of losing your health Dangerous substances...

Page 4: ...re not to use the wheels on thick carpet or to roll over objects as these could cause tipping DO NOT operate a unit that it has been dropped or damaged The appliance with electric heater shall have at...

Page 5: ...oke comes from it Do not operate or stop the unit by inserting or pulling out the power cord plug Do not use hazardous chemicals to clean or come into contact with the unit Do not use the unit in the...

Page 6: ...32 R290 Refrigerant only WARNING Thissymbolshowsthatthisapplianceusedaflammablerefrigerant Iftherefrigerant is leaked and exposed to an external ignition source there is a risk of fire CAUTION This sy...

Page 7: ...sion All possible ignition sources including cigarette smoking should be kept sufficiently far away from the site of installation repairing removing and disposal during which flammable refrigerant can...

Page 8: ...current permitted for the equipment in use Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere Replace components only with part...

Page 9: ...vicing or decommissioning it is recommended good practice that all refrigerants are removed safely Whentransferringrefrigerantintocylinders ensurethatonlyappropriaterefrigerantrecoverycylindersareempl...

Page 10: ...let 10 Lower air filter 11 Lower air intake 12 Drain outlet only for pump 13 Power plug socket 14 Power cord buckle 15 Power cord outlet 16 Bottom tray drain outlet NOTE All the pictures in the manual...

Page 11: ...prevail The unit can be controlled by the unit control panel alone or with the remote controller This manual does not include Remote Controller Operations see the Remote Control l Illustration packed...

Page 12: ...e adaptor is aligned with the hole seat of the air outlet and slide down the Exhaust hose assembly along the arrow direction for installation 3 STEP THREE Preparing the Adjustable Window Slider Depend...

Page 13: ...pe shorter Foam seal A Adhesive type Window slider A Window slider B if required Foam seal C Non adhesive type Foam seal C Non adhesive type 2 Screws Security Bracket Foam seal B Adhesive type shorter...

Page 14: ...Installation Note Cover the hole using the adaptor cap when not in use Expansion anchor position Adaptor cap Wall Exhaust Adaptor B max 120cm or 47 inch min 30cm or 12 inch Fig 13 NOTE To ensure prope...

Page 15: ...peed light optional 10 ION light optional 11 WiFi light optional Id Element Function 12 FOLLOW ME light optional 13 LED display 14 Degrees Celsius 15 Degrees Fahrenheit 16 SLEEP light 17 SWING WIFI bu...

Page 16: ...of time to connect to the network automatically 2 FAN ION button Ion is optional Control the fan speed Press to select the fan speed in four steps LOW MED optional HIGH and AUTO The fan speed indicato...

Page 17: ...ts call for service NOTE When one of the above malfunctions occurs turn off the unit and check for any obstructions Restart the unit if the malfunction is still present turn off the unit and unplug he...

Page 18: ...t 1 hour increments up to 24 hours The control will count down the time remaining until start The system will automatically revert back to display the previous temperature setting if there is no opera...

Page 19: ...setting temperature the unit will be automatically quit the power management feature The compressor and fan motor run 4 WATER DRAINAGE During dehumidifying modes remove the upper drain plug from the...

Page 20: ...eats call for service NOTE Be sure to reinstall the bottom drain plug firmly to prevent leakage before using the unit SCALE 0 500 SCALE 0 500 drain hose adaptor Continuous drain hose SCALE 0 500 SCALE...

Page 21: ...nit with a dry lint free cloth 3 STORE THE UNIT WHEN NOT IN USE Drain the unit s water collection tray according to the instructions in the following section Run the appliance on FAN mode for 12 hours...

Page 22: ...or is blocked Turn off the unit disconnect the hose check for blockage and reconnect the hose The unit is low on refrigerant Call a service technician to inspect the unit and top off refrigerant Tempe...

Page 23: ...EEP display Displays when SLEEP function is activated 9 FOLLOW ME display Indicates that the FOLLOW ME function is on 10 FRESH AIR display Not available for this unit 11 SILENT display Not available f...

Page 24: ...louver movement 7 SHORT CUT Sets and activates your favorite pre settings 8 TEMP Increases temperate in 1 C 1 F increments Max temperature is 30 C 86 F TEMP Decreases temperate in 1 C 1 F increments M...

Page 25: ...match up the and ends of the batteries with the symbols inside the battery compartment 3 Slide the battery cover back into place NOTE For optimum product performance Do not mix old and new batteries o...

Page 26: ...tart the unit NOTE FAN SPEED can t be changed in DRY mode 4 FAN operation 1 Press the MODE button to select FAN mode 2 Press FAN button to select the fan speed AUTO LOW MED or HIGH 3 Press the ON OFF...

Page 27: ...t a period of time after which the unit will automatically turn off such as when you wake up 1 Press the TIMER OFF button By default the last time period that you set and an h indicating hours will ap...

Page 28: ...hetimewillincreasein30minuteincrements with each press After 10 hours and up to 24 it will increase in 1 hour increments The timer will revert to zero after 24 hours You can turn off either function b...

Page 29: ...perature from the remote control instead of from the indoor unit itself will enable the air conditioner to optimize the temperature around you and ensure maximum comfort 1 Press FOLLOW ME button to ac...

Page 30: ...model Serial number Seller s stamp and signature Intaller s stamp and signature Sales data Invoice number Date of assembly Place of assembly Seller s stamp and signature I accept the terms of the war...

Page 31: ...Review date Service note Service stamp Signature 1 2 3 4 REGISTER FOR AIR CONDITIONERS PERIODIC REVIEWS Date of repair Service note Service stamp Signature 1 2 3 4 REGISTER OF REPAIRS...

Page 32: ...www rotenso pl email info rotenso pl Installer stamp...

Reviews: