Fig. 31 Detail
A Slave Cover Panel
B (4) 1/4-20NC x 1/2"
C Button Harness
D Slave Harness
E 1/2" Air Line
F Disconnect Harness
24. Slave Cable & Disconnect Harness Routing:
A) Remove cover panel from slave control side, Fig. 31
disconnecting the pushbutton cable from slave harness.
Do not unscrew the ground connection. Take one end of the
1/2" hose (40' provided) and push air line into the air fitting.
Air line should be clean and have a straight edge. Make
sure air line is not crimped before placing the slave hood
and access panel back on it's bracket. The air line
should be routed out of the slave control panel and back up
through the column and to the facility's main air supply. Air
fitting (provided) to make connection to main air supply, Figs.
31, and 31a.
B) Wire the disconnect harness into the bottom of the slave side
disconnect as shown in Fig. 31a. Facility power will be wired
into top of the slave side disconnect.
C) Run slave cable up through the column along hose routing.
D) Secure cable to structure with wire ties and away from
equalization cables.
E) Connect the master cable to the slave cable near the top of
the master column. If extension cables are needed connect
them between the master and slave cables.
F) Run the disconnect harness down the master column and
plug into master control and add extensions if necessary.
G) Do not attach the slave control panel to the back plate until
the gasket has been installed in Step 26.
B
A
D
C
B
E
F
Fig. 31
19