A
B
C
D
E
F
G
G
H
J
K
I
Fig. 30 Detail
A 5 wire power connection from slave control panel.
B Power harness or extension for power harness
follows hydraulic hose back to slave control panel.
C 3 wire from master control panel goes through stra-
in relief into junction box on powerunit motor.
D Strain Relief
E Grommet
Note: Secure all cables coming up from master
control panel to grommet hole with a wire tie when
hook-up is complete.
F Plug in lowering valve cord and tighten screw on
top to lock in place.
G Overhead Limit Switch
H From master cable connector
I N.O. Contacts
J White Wire
K Black Wire
Fig. 30