Enrollment
24
MD-W11 Installation Manual
A blinking TRBL LED indicates that there is trouble. Refer to
Section
4.2.1.3 for a list of possible problems.
4.2.1.2
Enrolling Mode
Enrolling mode is used for retention of transmitted data.
To set the Enrolling mode:
1.
Set DIP Switch 7 on both units (Near and Far) to Off.
2.
Power up both units.
3.
PWR LED is steady and ENRL LED is blinking.
4.
The Far Unit sends its ID to the Near Unit and the TX LED blinks
when transmitting.
5.
The Near Unit receives an ID and sends it to the Far Unit.
6.
The Far Unit receives the Near Unit’s ID and ENRL LED is lit
steadily.
7.
Set DIP Switch 7 on both units (Near and Far) to ON (normal
mode).
4.2.1.3
Trouble Mode
The MD-W11 Far module detects the following troubles:
Reader tamper
Far module tamper
Low battery
AC Fail
RF device failure/problem
Incorrect DIP switch setting