![Rosslare MD-W11BP Installation Manual Download Page 20](http://html1.mh-extra.com/html/rosslare/md-w11bp/md-w11bp_installation-manual_1489308020.webp)
Installation and Wiring
20
MD-W11 Installation Manual
TMP – Input for receiving reader tamper alert
Normally Open (NO)/Normally Closed (NC) and COM of 5A Form
C relay to the door’s lock
REX – Optional input for REX
DM – Optional input for door monitor contact
3.7
Installing the MD-W11BP Battery Pack
Only install the MD-W11BP battery pack in the MD-W11 Far Unit.
To install the battery pack:
1.
Use the spline key to remove the security screw from the bottom
of the case and open the unit.
2.
Use the drilling template to locate where to drill holes in the wall.
3.
Use the hardware provided to mount the back plate on the wall.
4.
Wire the battery pack as described in Section
3.8.
The battery pack comes with a battery installed. The size of the
case is compatible with Rosslare’s BT-05 12 VDC/800 mA SLA
rechargeable battery.
3.8
Wiring the MD-W11BP Battery Pack
In the Far Unit only, connect the Red (+) and Black (GND) to MDW11F
Bat (+) and Bat (-) (Figure 5)
3.9
Indications on the Near and Far Units
Figure 6 shows the six LEDs (that indicate the unit’s current status) on
the display panel of each unit.
Figure 6: LED Display Panel
PWR – Power ON
Tx – Sending transmission