Installation and Wiring 

20 

MD-W11 Installation Manual 

 

TMP – Input for receiving reader tamper alert 

 

Normally Open (NO)/Normally Closed (NC) and COM of 5A Form 
C relay to the door’s lock 

 

REX – Optional input for REX 

 

DM – Optional input for door monitor contact 

3.7

 

Installing the MD-W11BP Battery Pack 

Only install the MD-W11BP battery pack in the MD-W11 Far Unit. 

To install the battery pack: 

1.

 

Use the spline key to remove the security screw from the bottom 

of the case and open the unit. 

2.

 

Use the drilling template to locate where to drill holes in the wall. 

3.

 

Use the hardware provided to mount the back plate on the wall.  

4.

 

Wire the battery pack as described in Section 

 

3.8. 

 

The battery pack comes with a battery installed. The size of the 

case is compatible with Rosslare’s BT-05 12 VDC/800 mA SLA 
rechargeable battery. 

3.8

 

Wiring the MD-W11BP Battery Pack 

In the Far Unit only, connect the Red (+) and Black (GND) to MDW11F 
Bat (+) and Bat (-) (Figure 5) 

3.9

 

Indications on the Near and Far Units 

Figure 6 shows the six LEDs (that indicate the unit’s current status) on 
the display panel of each unit. 

Figure 6: LED Display Panel 

 

 

PWR – Power ON 

 

Tx – Sending transmission 

Summary of Contents for MD-W11BP

Page 1: ...MD W11 Wireless Access Control Door Interface Installation Manual MD W11BP MD W11F MD W11N...

Page 2: ...l property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL...

Page 3: ...ion Kit 13 3 2 General Installation Requirements 14 3 3 Installing the MD W11N Unit 14 3 4 Wiring the MD W11N Unit 15 3 5 Installing the MD W11F Unit 18 3 6 Wiring the MD W11F Unit 19 3 7 Installing t...

Page 4: ...Table of Contents iv MD W11 Installation Manual B Limited Warranty 28...

Page 5: ...allation Manual v List of Figures Figure 1 MD W11 Interface 8 Figure 2 MD W11 Back Cover 14 Figure 3 Near Unit Wiring Diagram 15 Figure 4 Sample Wiring Detail 17 Figure 5 Far Unit Wiring Diagram 19 Fi...

Page 6: ...List of Tables vi MD W11 Installation Manual List of Tables Table 1 DIP Switch Settings 22 Table 2 Unit Channels Setting 23...

Page 7: ...re not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effective...

Page 8: ...The Near Unit is connected to a Rosslare door controller such as AC 215 AC 225 or AC 525 The Far Unit is connected to proximity card readers or keypads such as AY K12 and AY Q64B When a card is read o...

Page 9: ...to increase security Four different RF channels to prevent collisions Built in charger for up to 12 VDC 7 Ah backup battery on the Far Unit Transfers proximity card information and LED control reader...

Page 10: ...s on RF link quality number of doors used and controller and reader response time Output Relays Far Unit One 5 A Form C relay Near Unit Two 1A Form C relays Output Types Far Unit LED CTRL open collect...

Page 11: ...4 in Weight Near Far Units 155 g 5 5 oz Battery Pack with battery 433 g 15 3 oz 2 1 Supported Card Transmission Formats Wiegand 26 Bit default Wiegand 26 Bit with Facility Code Output Wiegand 32 Bit W...

Page 12: ...Technical Specifications 12 MD W11 Installation Manual 2 3 Available Models MD W11NHR 869 MHz MD W11FHR 869 MHz MD W11NGR 433 MHz MD W11FGR 433 MHz MD W11BP...

Page 13: ...keypad and controls the door lock relay MD W11BP Battery Pack The battery pack is mounted only on the MD W11 Far Unit side see Section 3 7 The MD W11N and the MD W11F are connected to the controller...

Page 14: ...rity spline key One security hex screw Four mounting screws Four wall plugs Fixed external antenna G Model 3 3 Installing the MD W11N Unit The Near Unit can be connected to a standard Rosslare control...

Page 15: ...hly recommend using the bottom left mounting hole as it is acts as a back tamper when a person attempts to dislodge the unit from the wall see Figure 2 marked with A 4 Wire the unit as instructed in S...

Page 16: ...r LED control TMP Far Reader tamper LOCK Connection for lock input Relay 1 REX output Relay 2 Door monitor output System Tamper STAM Supervision Failure SPV Low Battery LBAT AC FAIL AC are outputs tha...

Page 17: ...5 225 525 The relevant input can be configured to result in the required outcome using AxTrax and Panel Links The connection between the REX Input and Relay 1 is always COM N O or COM N C so that only...

Page 18: ...it To install the Far Unit 1 Attach the battery box to the wall with two screws 2 Insert the wires from the reader and from the battery to the hole in the side of the Far Unit box 3 Attach the side of...

Page 19: ...the controller s input and output to the Far Unit as shown in Figure 5 Figure 5 Far Unit Wiring Diagram 12 24 VAC or 15 24 VDC to the VIN and VIN Optional backup battery that connects to BAT and BAT...

Page 20: ...the unit 2 Use the drilling template to locate where to drill holes in the wall 3 Use the hardware provided to mount the back plate on the wall 4 Wire the battery pack as described in Section 3 8 The...

Page 21: ...tion are improved if the Near and Far Units have the same polarity In addition Do not place any of the MD W11 units next to an air conditioner heater blower or an engine that generates a magnetic fiel...

Page 22: ...work together 4 2 DIP Switches The DIP switches on both units are set as shown in Table 1 Table 1 DIP Switch Settings DIP Switches 1 4 Not used Must be in the ON position DIP Switch 5 OFF or ON Used...

Page 23: ...the DIP switches have not been set properly In that case first re set the DIP switches and then power the unit off and on Only handle the DIP switches when the power is OFF 4 2 1 Near and Far Unit Mo...

Page 24: ...both units 3 PWR LED is steady and ENRL LED is blinking 4 The Far Unit sends its ID to the Near Unit and the TX LED blinks when transmitting 5 The Near Unit receives an ID and sends it to the Far Uni...

Page 25: ...LED flashes at a fast rate after power on Incorrect DIP Switch Setting All LEDs flash at a slow rate after power on The MD W11 Near module detects following troubles Near module tamper Supervision fai...

Page 26: ...s work with each other The Far Unit can also be attached to a REX button a door monitor to indicate whether a door is open or closed and a tamper to check whether the cover was opened These indication...

Page 27: ...protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc...

Page 28: ...nual B Limited Warranty The full ROSSLARE Limited Warranty Statement is available on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the War...

Page 29: ...sslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 5...

Reviews: