Rosslare InteliDoor AC-Q41H Instruction Manual Download Page 22

Page 42

07/04

AC-Q41H

Glossary

valid users. In this mode the door 

A

may be released by anyone pressing 

Access Control:

 Primarily refers to 

the star button.

a device or set of devices controlling 

C

the entry of people traveling through 
a door or set of doors.

Cards:

 See Proximity Cards

Ajar Delay:

 The time allowed for a 

Case Tamper:

 The electronic 

door to be left open before sounding 

tamper signal advising the controller 

an alert and / or activating the 

that 

the 

case 

has 

been 

opened.

Auxiliary Relay.

Code Assignment:

 The process of 

Amplitude Shift Keying (ASK): 

The 

assigning which Output(s) (Lock 

typ e  of  dat a  com mun ica tio ns 

Strike Relay and / or Auxiliary Relay) 

between the  Proximity Card  and the 

are to be activated when a valid code 

Proximity Reader.

is entered.

ASK:

 An abbreviation of "Amplitude 

D

Shift Keying".

Direct Shunt: 

The arrangement in 

Auxiliary Input:

 The term used for 

which an external input (such as a 

the programmable input electrical 

door monitor) is connected directly to 

signal from an  external device such 

the Auxiliary Relay allowing the 

a Door Monitor switch or Auxiliary 

Auxiliary Output to be activated after 

REX button.

the direct shunt delay elapses. This 

Auxiliary Code:

 The four digit code 

leaves the Auxiliary Input available 

used to activate the Auxiliary Output 

for Normal / Secure mode toggle.

f o r   t e s t i n g   p u r p o s e s   d u r i n g  

Default Factory Setting:

 The 

installation.

settings that the controller is 

Auxiliary Output:

 The term used for 

preprogrammed with when the 

the Relay Output in the AC-Q41H 

controller is manufactured.

that may be programmed to activate 

Direct Shunt  Delay: 

The delay time 

upon different system events such as 

(user programmed) used in Direct 

Tamper, Forced Door Event, Door 

Shunt (See Direct Shunt).

Ajar, etc.

Door Bell:

 The alert sound activated 

B

when the door star button on the AC-

Back Tamper:

  The   ele ctr oni c 

Q41H is pressed. (Requires the BL-

tamper signal advising the controller 

D40 External Sounder)

that the controller has been removed 

Door Chime:

 The alert sound 

from 

the 

wall.

activated when the lock strike 

Bypass Code: 

The four digit code 

unlocks the door after a valid code 

used  to ch ange  the M ode o f 

has been presented. (Requires the 

Operation of the AC-Q41H from 

BL-D40 

External 

Sounder)

Normal to Bypass Mode or vice 
versa.

Bypass Mode: 

A Mode of Operation 

where door access is not restricted to 

Page 43

07/04

AC-Q41H

Replacing a lost Programming Code

1) 

Remove power from the 

2)

 Press the REX button

3) 

Apply power to the unit with REX button pressed

4)

 Release the REX button

5)

 You now have 15 seconds to program a new Programming Code 

into the unit using the initial default code 1234, before the 
controller reverts to the existing code.

Replacing a lost Normal / Secure Code

1) 

Remove power from the AC-Q41H

2)

 Press the REX Button

3) 

Apply power to the unit with REX button pressed.

4)

 Release the REX Button

5)

 You now have 15 seconds to use the default Normal / Secure 

code 3838 in order to return to normal mode, where you may 
enter programming mode to program a new Normal / Secure 
Code.

Note:

The AC-Q41H must be in Normal Mode otherwise this 
will not work. Make sure that the Mode LED is green 
before proceeding.

AC-Q41H

Note:

The AC-Q41H must be in Secure Mode otherwise this 
will not work. Make sure that the Mode LED is red before 
proceeding.

Summary of Contents for InteliDoor AC-Q41H

Page 1: ...INSTRUCTION MANUAL AC Q41H VANDAL RESISTANT STAND ALONE ACCESS CONTROL UNIT 07 04 1 2 3 4 5 6 7 8 9 0 ...

Page 2: ...e Programming Code 24 4 Changing the Normal Secure Code 25 5 Changing the Normal Bypass Code 25 Door Chime Settings 25 6 Setting Fail Safe Secure Operation 27 Setting Tamper Siren Time 27 Setting the Lock Strike Release Time 27 Setting the Auxiliary Mode 28 Auxiliary Mode Quick Reference Table 29 Auxiliary Mode Reference Guide 30 Enabling or Disabling the built in Keypad Heater 33 7 Enrolling Prim...

Page 3: ...r AC Q41H Other Rosslare accessories can be found at Rosslare s Web Site http www rosslaresecurity com AC Q41H 07 04 Technical Specification Electrical Characteristics Operating Voltage Range 12 to 24V DC From a Regulated Power Supply or 16 to 24V AC From a Transformer Maximum Input Current when heating is inactive At 12V DC Standby 40mA Not including attached devices Max 100mA Not including attac...

Page 4: ... LED Control Internal Buzzer Comes with security screw and security screw tool Two Tri Color LED s for Status Programming Interface Three User Levels Normal User Secure User Master User Three Modes of Operation Normal Mode Bypass Mode Secure Mode Code Search feature that helps make maintaining user codes easier Input for Request to Exit REX button Comes with mounting template for easier installati...

Page 5: ...ee explanation and diagram below US Gang Box There are two hole indicators on the back of the metal cover specifically for the US Gang Box Shown marked as A 4 Screw Custom There are four indicators on the back Shown marked as B 3 Drill the exit entry holes for the wiring Shown marked as C 4 Pass the wires through the exit entry holes and attach them to the controllers removable terminal blocks as ...

Page 6: ...Controller 7 Return the front cover of the AC Q41H to the mounted back plate 8 Secure the front cover by using the supplied security screw in the controllers accessories kit An L Shaped tool is provided for use when tightening the security screw Wiring the AC Q41H A few of the typical wiring diagrams are shown on the next three pages for other wiring diagram examples refer to the support section o...

Page 7: ...N POWER SUPPLY 12V 24V DC or 16V 24V AC FROM TRANSFORMER Transorb 1 5KE47C Connect to load terminals Optional transorb Not Supplied COM N C N O REX BL COM N C N O IN MONITOR LOCK AUX V IN COMMON POWER SUPPLY 12V 24V DC or 16V 24V AC FROM TRANSFORMER Auxiliary Load AUXILIARY INPUT MONITOR AUX IN IN MONITOR Transorb 1 5KE47C Connect to load terminals Optional transorb for inductive loads Not Supplie...

Page 8: ...hree Modes of Operation There are three user levels Normal User A Normal User only has a Primary Code and is only granted access when the AC Q41H is in Normal or Bypass Mode Secure User A Secure User must have a Primary and Secondary Code programmed the two codes must not be the same The Secure User can gain access when the AC Q41H is in any of its three Modes of Operation In Normal Mode the Secur...

Page 9: ...r entering their Primary code the Door LED will flash green for 10 seconds during which the Secondary Code must be entered A Master User only needs to enter their PIN code once to gain entry The AC Q41H has 3 Modes of Operation 1 Normal Mode Mode LED is green Normal Mode is the default mode In Normal Mode the door is locked until a Primary Code is presented to the controller The controller can onl...

Page 10: ...the controller is removed from the wall a tamper event is triggered A coded tamper signal is then sent to the BL D40 or other compatible device If the BL D40 External Sounder receives a Tamper Event Signal it will activate a Siren and a Strobe Light The Siren time can be easily programmed in the AC Q41H from 0 to 9 minutes The tamper event can activate the Auxiliary Output if the controller is in ...

Page 11: ...uctions for each of the above menu items on the following pages Menu Description Factory Settings Menu Number Page 21 07 04 AC Q41H BL D40 External Sounder The BL D40 External Sounder is designed to operate indoors and installed within the premises to be secured The Sounder can be powered by 16 to 24V DC power supply or by 16 to 24V AC from a transformer The BL D40 is capable of emitting four diff...

Page 12: ...e controller or the open code is changed the default Auxiliary Code will automatically be deleted ready for an Auxiliary Code to be assigned Mode Door GREEN Mode Door GREEN RED Mode Door GREEN Entering Programming Mode Exiting Programming Mode 1 Press the key two times within 2 seconds l Mode LED will turn off l Door LED will turn red 2 Enter your 4 digit Programming Code If the Programming Code i...

Page 13: ... Bypass Mode Disable Door Chime d Enable Bypass Mode Enable Door Chime Mode Door GREEN Mode Door GREEN RED Mode Door GREEN Mode Door GREEN Mode Door GREEN ORANGE 1 Enter Programming Mode 2 Press 2 to enter Menu 2 l The Mode LED will turn orange 3 Enter the new 4 digit code you wish to set as Auxiliary Code 4 System returns to Normal Mode l You will hear three beeps l The Door LED will turn off l T...

Page 14: ...rike to be released For example 0 5 1 2 means Fail Secure Operation with a 5 minute Tamper Siren Time and a 12 second Lock Strike release time 4 System returns to Normal Mode l You will hear three beeps l The Door LED will turn off l The Mode LED will turn green Mode Door GREEN Mode Door GREEN Mode Door GREEN GREEN a Disable Bypass Code Disable Door Chime Enter the 4 digit code 0000 b Disable Bypa...

Page 15: ...lays are in seconds Page 28 07 04 Setting the Auxiliary Mode The default auxiliary setting is 2004 1 Enter Programming Mode 2 Press 6 to enter Menu 6 l The Mode LED will flash green 3 Construct the 4 digit code using the instructions below Auxiliary Mode Auxiliary Setting Auxiliary Mode In addition to the Lock Strike Relay and Lock Strike REX the AC Q41H features an Auxiliary Output Relay and an A...

Page 16: ...orced door delay time and then activate the auxiliary relay The auxiliary setting defines the forced door delay AC Q41H Page 31 07 04 AC Q41H Auxiliary Mode Reference Guide The following are brief descriptions of each of the AC Q41H s auxiliary modes To use these features refer to Setting the Auxiliary Mode on page 28 AUXILIARY MODE 0 In auxiliary mode 0 the AC Q41H can function as a two door cont...

Page 17: ...e the ajar delay time the controller will activate the auxiliary relay The auxiliary setting defines the door ajar time If the BL D40 is connected and an ajar event occurs the BL D40 will chime every few seconds for 1 minute or till the door is closed AUXILIARY MODE 8 In auxiliary mode 8 the AC Q41H can function as a two door controller and also provide LED Control functionality The auxiliary rela...

Page 18: ...E Mode Door GREEN GREEN Mode Door RED GREEN Enrolling Primary Secondary Codes Primary Codes Primary Codes can only be enrolled to an empty User Slot i e a slot where there is no existing Primary Code Primary Codes must be unique i e one users Primary Code may not be the same as another users Primary Code Primary Codes cannot be the same as any system codes such as the Normal Secure Code or Open Co...

Page 19: ...o keep track of which user slots are empty and which user slots are not Mode Door GREEN Mode Door ORANGE RED Mode Door ORANGE RED Enrolling Secondary Codes using the Code Search Method The Code Search feature enables you to quickly enroll a Secondary Code to a user who s slot number is unknown but who s primary code is known 1 Enter Programming Mode 2 Press 7 to enter Menu 7 l The Door LED will tu...

Page 20: ...ler is now waiting for another slot number Press the key to go to the next slot or enter a new slot number or if you do not wish to continue press the key two times and the controller will return to Normal Mode Mode Door GREEN Mode Door ORANGE GREEN Mode Door ORANGE GREEN Mode Door ORANGE GREEN Deleting Primary and Secondary Codes using the Code Search Method 1 Enter Programming Mode 2 Press 8 to ...

Page 21: ...k Strike and Auxiliary Relay Code Assignment using the Code Search Method 1 Enter Programming Mode 2 Press 9 to enter Menu 9 l The Mode LED will turn red 3 Enter the 3 digit User Slot 000 l The Door LED will flash orange The controller is now waiting for the Primary Code of the user you want to Code Assign 4 Enter the 4 digit PIN Code of the Primary Code belonging to the user you want to assign a ...

Page 22: ...ed that may be programmed to activate Direct Shunt Delay The delay time upon different system events such as user programmed used in Direct Tamper Forced Door Event Door Shunt See Direct Shunt Ajar etc Door Bell The alert sound activated B when the door star button on the AC Back Tamper The ele ctr oni c Q41H is pressed Requires the BL tamper signal advising the controller D40 ExternalSounder that...

Page 23: ...leaves the versa connected door locked Normal User A user who only has a Forced Door A door which has Primary Code and can only gain been physically opened without the access in Normal Mode access control device having Normally Closed A relay output released the lock from the controller that is activated Forced Door Time The amount of closed circuit under normal time user programmed the conditions...

Page 24: ...y Rosslare s LIMITED LIFETIME WARRANTY is subject to the following conditions WARRANTY Warranty of Rosslare s products extends to the original purchaser of the Rosslare product and is not transferable WARRANTY DURATION Rosslare warrants this product against defects in material and or workmanship for the life of the product from the date of original purchase to the original purchaser WARRANTY COVER...

Page 25: ...on Bay Hong Kong http www rosslaresecurity com Tel 852 2795 5630 Fax 852 2795 1508 E mail info rosslare com hk United States and Canada Rosslare NAPDC Suite 238 200 East Howard Street Des Plaines IL 60018 USA http www rosslaresecurity com Tel 866 262 8633 T oll Free Tel 847 827 6330 Direct Fax 847 827 6433 E mail support rosslare net ...

Reviews: